CONSULT LOCAL ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL SERVICE PERSONNEL.
Symptom
Breaker trips immediately
upon energizing heater.
Heater fan operates, but
does not discharge warm
air.
Heater will not shut off.
Heater discharges smoke
or emits a burnt odor.
Element heats for a
moment without the fan
turning, then immediately
stops heating.
Heater does not run.
LIMITED ONE-YEAR WARRANTY: Cadet will repair or replace any Cadet product,
including thermostats, found to be defective within one year after the date of purchase.
Extended Product Warranty
LIMITED THREE-YEAR WARRANTY: Cadet will repair or replace any Com-Pak
Bathroom Heater (CB) series element or motor found to be defective or malfunctioning
from first date of purchase through the third year.
These warranties do not apply:
1. Damage occurs to the product through improper installation or incorrect supply
voltage;
2. Damage occurs to the product through improper maintenance, misuse, abuse,
accident, or alteration;
3. The product is serviced by anyone other than Cadet.
4. If the date of manufacture of the product cannot be determined;
5. If the product is damaged during shipping through no fault of Cadet.
6. CADET'S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT AS SET OUT HEREIN.
CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY DAMAGE OR FOR
P.5

IMPORTANT INSTRUCTIONS

WARNING
Turn the electrical power off at the electrical panel board (circuit breaker or fuse box) and lock or tag the
panel board door to prevent someone from turning on power while you are working on the heater. Failure to
do so could result in serious electrical shock, burns, or possible death.

Troubleshooting Chart

Problem
1.Incorrect supply voltage.
2.Overloaded circuit.
3.A short circuit exists in the
supply or heater wiring.
4.Defective circuit breaker.
1.Insufficient element temperature.
2.Incorrect supply voltage.
3.Element has failed.
1.Heat loss from room is greater
than heater capacity.
2.Thermostat is not functioning
properly.
1.Dust, lint or other matter has
accumulated inside heater.
1.Defective motor or internal
connection.
2.Fan or motor jammed.
1.Thermostat set too low.
2.Heater has tripped the manual
high-temperature reset switch.
3.Heater has tripped the secondary
over-temperature switch.
4.Power not on at the circuit
breaker.
5.Broken or poorly connected
wire(s) to heater.
6.Defective thermostat and/or
timer.
©2007 Cadet Manufacturing Co.
Solution
1. Verify that supply voltage matches the heater rating.
2. The total amperage of all heaters on a branch circuit must not be more
than 80% of the amperage rating of the circuit breaker and supply wire
ratings. Use a lower wattage heater, or reduce the number of heaters on
the circuit.
3. Shorted supply or heater wires may be accompanied by severe sparking.
Inspect all supply and heater wiring insulation for damage. Do not reset
the circuit breaker until all electrical shorts have been repaired.
4. Replace the circuit breaker.
1. Allow a few moments for element to reach operating temperature.
2. Verify that supply voltage matches the heater rating.
3. Replace element.
1. Close doors and windows. Provide additional insulation, or install a
higher wattage heater or multiple heaters if necessary. (If your circuit is
rated for more capacity.)
2. Wait for the timer to time-out or turn the timer counterclockwise to `0'
(The timer overrides the thermostat setting). If heater continues to run,
adjust thermostat to its lowest setting. If heater continues to run (allow
two minutes for the thermostat to respond), and room temperature is
greater than 50 degrees; the thermostat requires replacement.
1. Clean heater (See "Operation & Maintenance" section for instructions).
1. Heater or fan motor requires replacement.
2. Remove obstruction and press heater reset button (after allowing the unit
to cool). Test heater operation--if reset button has been pressed (be sure
to listen and feel for a click indicating it has been reset), but heater does
not run, heater requires repair or replacement.
1. Adjust thermostat to a higher temperature until heater operates (see
Problem #6 if the problem persists).
2. Press the manual reset button (See "Operation & Maintenance" section
for instructions).
3. A severe over-temperature condition has occurred. Repair or replace
heater.
4. Turn on the correct circuit breaker in the main panel.
5. Turn off power at circuit breaker. Check supply wire continuity and proper
connection to heater wires.
6. Repair or replace the heater. The entire heater, or any of its components
may be checked for continuity to determine the cause of any problem.
Warranty
CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL EXPENSES RESULTING FROM
BREACH OF THESE WRITTEN WARRANTIES OR ANY EXPRESS OR IMPLIED
WARRANTY.
7. IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET PRODUCT,
THE REPLACEMENT PARTS ARE SUBJECT TO THE SAME WARRANTIES AS THE
PRODUCT. THE INSTALLATION OF REPLACEMENT PARTS DOES NOT MODIFY OR
EXTEND THE UNDERLYING WARRANTIES. REPLACEMENT OR REPAIR OF ANY
CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES.
8. These warranties give you specific legal rights, and you may also have other rights
which vary from state to state. Cadet neither assumes, nor authorizes anyone to
assume for it, any other obligation or liability in connection with its products other
than as set out herein.
If you believe your Cadet product is defective, please, contact Cadet Manufacturing Co.
at 360-693-2505, during the warranty period, for instructions on how to have the repair
or replacement processed. Warranty claims made after the warranty period has
expired will be denied. Products returned without authorization will be refused.
Parts and Service
Contact Cadet for information on Parts or Service.
Printed in U.S.A. Rev. 01/07 #720050

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

The com-pak cb103t

Tabla de contenido