Supply voltage
Frequency
Current consumpt ion

Technical Specifications

Power
NOTE: The system doesn't support a mixed installation of 1200 W and 1400 W power supply
units.
NOTE: Both the 1200 W and 1400 W PSUs are hot swappable, and they can support hot swap in
any condition i f the system has the power throttling feature.
AC powe r su pply (pe r powe r su pply)
Watt age
Voltage
Heat dissip ation
M aximum inrush current
Watt age
Voltage
Heat dissip ation
M aximum in-rus h current
Getting Started With Your System
100-240 V AC w ith 1200 W P ower
Supply U nit
200-240 V AC w ith 1400 W P ower
Supply U nit
50/60 Hz
12-8 A mps w ith 1200 W P ow er Supply
Unit
9 A mps w ith 1400 W P ow er Supply
Unit
1200 W
100-240 VA C, 50/60 Hz, maximum input
current: 12.0-8.0 A mps
NOTE: For 1200 W power supply, output 1200 W is for
high line (input 200-240 VAC), output 1023 W is for low
line (input 100-120 VAC).
4016.251 BTU /hr maximum
Initial In-rus h Current cannot exceed 55
A mps (p eak). Secondary In-rush Current
cannot exceed 35 A mp s (p eak).
1400 W
200-240 VA C, 50-60 Hz , maximum input
current: 9.0 A mps
6024.376 BTU /hr maximum.
Initial In-rus h Current cannot exceed 55
A mps (p eak). Secondary In-rush Current
cannot exceed 25 A mp s (p eak).
|