Before connecting to the mains electricity supply make sure that:
The wiring and mains supply are suitable for the appliance. All information is given on the rating plate affixed
to the front of the oven.
Type of cable to be used not lighter than type H05VV-F or H05RR-F. Minimum section of the cable for ovens
of 3500 Watt is 3 x 1,5mm2.
The appliance has been earthed conforming with the safety regulations and law in force. Earthing is obligatory
by law. In the event the appliance is not supplied with a power cable and/or appropriate plug only use materials
suitable for the electrical input given in the rating plate affixed to the appliance. The power cable must not
under any circumstances, along any point, reach a temperature higher than 50° C room temperature. If you
wish to connect the appliance directly to the mains electricity supply it is necessary to wire an omnipolar
switch with a minimum opening of 3 mm between the contacts. This switch must be dimensioned for the
power rating and must conform to the safety and electrical standards in force (the yellow-green earth wire must
not under any circumstances be cut off by the omnipolar switch). The socket or the omnipolar switch must be
in an easily accessible position with the appliance installed.
First of all it is important to check the water hardness. We strong suggest to install a descaling system in the case of
hard water (more than 7°). You can find out the hardness of the water by consulting your waterworks or using a test
strip.
The oven has an electronic safety valve on the incoming water line and a second safety valve that allow the steam to
work only when the oven is functioning and has reached an inside temperature of about 100°C, it is however suggested
to install the acquastop.
specialised plumber have to connect the oven to the water network, use a normal waterhose tube for dishwasher.
attach the tube the the cold water faucet.
If the tube is being attached to new pipes that have not been used for a long time, you should let the water run for some
time before attaching the tube in order to make sure that dirt and rust residues are eliminated.
The oven is supplied from the manifacturer with a calibration of 4 atmosphere , please check the water pressure at the
installation place.
N.B. The manufacturer declines all responsibility in the event the foregoing instructions and the accident
prevention standards in force are not respected. The manufacturer further declines all responsibility in the
event there are inaccuracies in this booklet due to printing or copying errors. The manufacturer reserves the
right to improve, modify or make any changes considered necessary to its products without impairing the
essential features.

Electric connection

Water connection

GB