Escutcheon
Valve
Body
Apply
Washer
plumbers
Nut
putty.
Hose Quick
Quick
Connect
Connect
Tee

3. Valve Installation

Apply a bead of plumbers putty or other sealant to the underside
of the escutcheons according to the manufacturer's instructions.
Insert the valve bodies into the mounting holes from the top of
the sink. Make sure the hot valve body is installed in the
left-hand hole and the cold valve body is installed in the
right-hand hole.
Install a washer and nut to the bottom of the valve bodies.
Wrench tighten the nuts.
Remove any excess plumbers putty.
Connect and tighten the hoses to the valves.
Connect all three hoses to the quick connect tee.
4. Supply Installation
Connect the supply hoses to the handle valves, and the supply
stops. Left is hot and right is cold.
Tighten all connections.
1036179-2-C
Valve
Body
Outlet
Sink
Supply
Tube
Hot
Supply
Stop
4
Cold
Supply
Stop