DT1100-TN19
OWNER'S MANUAL
FLYING INSECT TRAP
Thank you for purchasing
the DYNATRAP
®
flying insect trap!
This product may be covered by one or more U.S. patents
or pending patent applications. See www.DynaTrap.com/patents
IMPORTANT, RETAIN FOR FUTURE
REFERENCE: READ CAREFULLY
WARNING: When using electric appliances, basic precautions should always be followed, including the following:
– To disconnect, turn all controls to the off ("O") position, then remove plug from outlet.
– Unplug from outlet when not in use and before servicing or cleaning.
– To reduce the risk of electrical shock, do not put appliance in water or other liquid.
– This appliance is provided with double insulation. Use only identical replacement parts.
CAUTION: To reduce the risk of injury from moving parts, unplug before servicing.
WARNING: Risk of Electric Shock.
See instructions for Servicing of Double-Insulated Appliances.
IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions before using the DynaTrap
®
Insect Trap and keep for future reference.
1. Always turn unit off and disconnect plug before servicing or cleaning.
2. Do not position the unit near heat, gas, oil or other flammable materials.
3. Mount out of reach from children.
4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or if it has been dropped into water.
5. The electrical adapter provided with this product is equipped with a 2-conductor cord and a 2-prong.
If the plug does not fully fit in the outlet, contact a qualified electrician. To reduce the risk of electrical shock,
only plug into a properly installed outlet. Do not attempt to defeat this safety feature.
6. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
7. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
8. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
9. Do not touch fan while in motion.
10. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.
Keep cord away from sharp edges.
11. If using outdoors, use only extension cords with a tag stating "Suitable for Use with Outdoor Appliances".
12. Use only extension cords that have plug and receptacles that match the product plug.
Replace or repair damaged cords.
13. Only use attachments recommended or sold by the manufacturer
14. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation
are provided instead of grounding. No grounding means is provided on a double insulated appliance, nor should
a means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme
care and knowledge of the system, and should be done only by qualified service personnel. Replacement parts
for a double-insulated appliance must be identical to those parts in the appliance. A double-insulated appliance is
marked with the words "DOUBLE INSULATION", "DOUBLE INSULATED" or the
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
2. If hanging or mounting the trap place approximately 3–6 feet above the floor/ground level for optimal catch
rate and easy access for cleaning.
3. If mounting the trap to a wall, secure the mounting bracket to a wall, fence, or other stationary surface using the
mounting hardware (included). Then, mount the trap on the bracket by sliding the mounting channel on the side wall
of the trap over the mounting bracket peg.
4. Turn power switch to "ON" position (The power switch is located under the rain protector).
5. If using outdoors, plug cord into an outdoor extension cord as described in
"IMPORTANT SAFETY INSTRUCTIONS".
6. For best catch results leave unit on at all times, except when cleaning or servicing.
7. If using outdoors, it is recommended to place the unit 20-40 feet away from where people will be sitting.
8. Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from competing
light sources. Intended for household use only.
9. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will
fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
USER MAINTENANCE INSTRUCTIONS - CLEANING
Clean the trap at least once a week to prolong life of the unit, insure fire prevention, and provide for more efficient operation.
1. Be sure to clean the unit once per week
2. Unplug before cleaning
3. For weekly cleaning, twist the cage clockwise, and remove the damper by grasping the crossbar near the edge of the
damper. Pull up firmly. Remove any buildup from the inside of the retaining cage and fan with a brush (included).
Replace damper, snap firmly into place.
4. For major cleaning, remove the screws securing the fan housing to the light housing. After removing the screws,
gently pull the fan housing away from the light housing. Using a soft brush, remove dirt and debris from the light
housing. Once the cleaning process has been completed, align the screw holes in the fan housing with the screw holes in
the lighting unit and tighten the screws to the base of the lighting unit.
5. When replacing the retaining cage – DO NOT press / push against the screen windows.
REPLACING BULB Replace With DynaTrap Bulb #41050 (or equivalent G24 Type - 120V/7W UVA Bulb)
The Light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure
optimal UV effectiveness. Even though the bulb's light may be visible to you, its ability to attract insects diminishes over time.
1. UNPLUG UNIT, and allow bulb to cool before replacing.
2. Remove screw (A). Twist cover counter-clockwise (B). Tilt cover back to expose bulb (C). Note: Upper and lower sections
will remain connected by electrical wire - Do Not Pull or Attempt To Disconnect.
3. Untighten the screw securing the base of the light bulb to the light housing. Slide the metal clip to the side. Cover the
bulb with a cloth to protect your finger and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and
gently pull the bulb from the socket.
4. Remove any debris from the lamp socket with a brush before inserting the new bulb. Replace the metal clip over the
base of the bulb and tighten the retaining screw.
5. Replace cover onto grill and twist clockwise to lock, replace screw and tighten to secure.
A
symbol.
HOW THE DYNATRAP
Flying insects are attracted to the unit by
UV light and CO2 that is generated by the
photo-catalysis between the UV lamps and
special TiO2 coating. The fan then pulls the
insects into the screened base, trapping
them until they dehydrate and die. The
base can be removed, allowing the contents
to be periodically emptied into the trash.
TROUBLESHOOTING
Problem:
Bulb does not illuminate
and fan does not spin.
Bulb illuminates, but fan
does not spin.
Fan spins, but bulb does
not illuminate.
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This
warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain
your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or
abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the
United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential,
or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states
do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
REPLACEMENT PARTS
41050
To see all replacement and accessory parts available for your DynaTrap,
including UV-bulbs, fans, retaining cages, and more, visit www.DynaTrap.com.
SAVE THESE INSTRUCTIONS
FOR HOUSEHOLD AND COMMERCIAL, INDOOR AND OUTDOOR USE
B
Dynamic Solutions Worldwide, LLC
C
12247 W. Fairview Ave. Milwaukee, WI 53226
1-877-403-TRAP (8727)
customercare@dsw-llc.com
Visit us online at www.DynaTrap.com
©2018 Dynamic Solutions Worldwide, LLC
INSECT TRAP WORKS
®
HANGER
UV
BULB
FAN
RETAINING
CAGE
Possible cause:
Correction:
GANCHO PARA
COLGAR
No electrical power.
1. Check plug, receptacle, and fuse or circuit breaker.
2. Check to make sure power is switched to the "ON" position.
Shorted fan.
UNPLUG UNIT: Examine fan to see that it is free from
FOCO
foreign material, dirt or build-up of dead insects.
ULTRAVIOLETA
Clean unit as in "CLEANING" section.
1. Bulb not seated
1. Check all sockets for proper bulb seating and alignment.
properly
2. Replace bulb if needed following instructions under
VENTILADOR
"Replacing Bulb"
2. Burnt out bulb
CAMARA DE
RECOLECCION
7-Watt Replacement UV Fluorescent Bulb (1 piece)
This device complies with Performance Standards
for Light-Emitting Products, 21 DFR, Part 1040,
Chapter 1, Subchapter J, Radiological health.
ON/OFF
SWITCH
TiO
2
COATED
SURFACE
WALL
MOUNT
AUTOMATIC
DAMPER
INTERRUPTOR
PARA PRENDER
O APAGAR
SUPERFICIE
CON CAPA
DE TiO
2
SOPORTE
DE PARED
COMPUERTAS
AUTOMATICAS