Door Opening Time Adjustment; Adjusting Open Door Time - Fermax 2260 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Door opening time adjustment

This parameter, adjustable between 1 and 99, represents the time in seconds
that the door release remains activated after an activated card has been shown.
Beep!
Beep!
Beep!
-
+
+
1. Show the MASTER card
(three times).
The indicators will display
the"door release activation
time configuration mode"
setting.

Adjusting open door time

This parameter, adjustable between 0 and 99, represents the time in seconds
after which the reader's built-in sonic alarm will start to sound, while the door
stays open. Installation of a magnetic door sensor is required. See diagram.
Initially, this function is disabled (value 0). To enable it, you must follow these
steps:
Beep!
Beep!
Beep!
Beep!
-
+
+
1. Show the MASTER card
(four times).
The indicators will display
the "door open time
configuration mode."
NOTE:
The first time that a card is shown disables this options. The other ones enable
the system and increase the time in seconds.
-
2. Show any card (except the MASTER)
as many times as seconds to be set for
door release activation.
One time: one second
Two times: two seconds...
-
2. Show any card (except the MASTER)
as many times as seconds to be set for
open door detection.
See note below.
Beep!
Beep!
-
-
+
+
Beep!
Beep!
-
+
-
+
Beep!
Beep
+ -
3. Show MASTER card at
the end, until indicators
display "normal mode."
Beep!
+ -
3. Again show the MASTER
card at the end, until
indicators display "nor-
mal mode."
Pag 15
+ -
+ -

Publicidad

Tabla de contenido
loading

Tabla de contenido