19, 49
2 Bytes
S
20, 50
2 Bytes
S
21, 51
2 Bytes
S
1 Bit
E
22, 52
1 Bit
E
23, 53
1 Bit
E
24, 54
1 Bit
S
25, 55
1 Bit
E
26, 56
1 Bit
S
27, 57
1 Byte
S
28, 58
1 Byte
S
1 Bit
S
29, 59
1 Bit
S
1 Bit
S
30, 60
1 Bit
S
31, 61
1 Bit
S
32, 62
1 Bit
S
33, 63
1 Bit
S
34, 64
1 Bit
S
65, 69, 73, 77 2 Bytes
S
66, 70, 74, 78
1 Bit
S
67, 71, 75, 79
1 Bit
S
68, 72, 76, 80
1 Bit
S
81
1 Byte
E
82
1 Byte
83, 112, 141,
1 Byte
S
170
84, 113, 142,
1 Bit
S
171
85, 114, 143,
1 Bit
S
172
86, 115, 144,
1 Byte
S
173
87, 116, 145,
1 Byte
S
174
88,117, 146,
1 Bit
S
http://www.zennio.com
C T R - -
DPT_Value_Temp
-273,00 - 670760,00
C T R - -
DPT_Value_Temp
-273,00 - 670760,00
C T R - -
DPT_Value_Tempd
-670760,00 - 670760,00 [Tx] Consigna (Estado de Offset)
C - - W -
DPT_Reset
C - - W -
DPT_Reset
C - - W -
DPT_Heat_Cool
C T R - -
DPT_Heat_Cool
C - - W -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Scaling
C T R - -
DPT_Scaling
C T R - -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Switch
C T R - -
DPT_Value_Temp
-273,00 - 670760,00
C T R - -
DPT_Alarm
C T R - -
DPT_Alarm
C T R - -
DPT_Alarm
C - - W -
DPT_SceneControl
0-63; 128-191
C T - - -
DPT_SceneControl
0-63; 128-191
C T R - -
DPT_Scaling
C T R - -
DPT_Alarm
C T R - -
DPT_Alarm
C T R - -
DPT_Scaling
C T R - -
DPT_HVACMode
C T R - -
DPT_Occupancy
[Tx] Consigna (Estado)
[Tx] Consigna Básica (Estado)
0/1
[Tx] Reinicio de Consigna
0/1
[Tx] Reiniciar Offsets
0/1
[Tx] Modo
0/1
[Tx] Modo (Estado)
0/1
[Tx] On/Off
0/1
[Tx] On/Off (Estado)
0% - 100%
[Tx] Variable de Control (Enfriar)
0% - 100%
[Tx] Variable de Control (Calentar)
0/1
[Tx] Variable de Control (Enfriar)
0/1
[Tx] Variable de Control (Enfriar)
0/1
[Tx] Variable de Control (Calentar)
0/1
[Tx] Variable de Control (Calentar)
0/1
[Tx] Frío Adicional
0/1
[Tx] Calor Adicional
0/1
[Tx] Estado de PI (Enfriar)
0/1
[Tx] Estado de PI (Calentar)
[Ex] Temperatura actual
0/1
[Ex] Sobreenfriamiento
0/1
[Ex] Sobrecalentamiento
0/1
[Ex] Error de sonda
[Detec. Mov.] Escenas: entrada
[Detec. Mov.] Escenas: salida
0% - 100%
[Ex] Luminosidad
0/1
[Ex] Error de circuito abierto
0/1
[Ex] Error de cortocircuito
0% - 100%
[Ex] Estado de presencia (Porcentaje)
1=Confort
2=Standby
[Ex] Estado de presencia (HVAC)
3=Económico
4=Protección
0/1
[Ex] Estado de presencia (Binario)
MAXinBOX FC 0-10V VALVE
Consigna actual
Consigna básica actual
Valor actual del offset
Reinicio a valores por defecto
Reiniciar offset
0 = Enfriar; 1 = Calentar
0 = Enfriar; 1 = Calentar
0 = Apagado; 1 = Encendido
0 = Apagado; 1 = Encendido
Control PI (Continuo)
Control PI (Continuo)
Control de 2 puntos
Control PI (PWM)
Control de 2 puntos
Control PI (PWM)
Temp >= (Consigna+Banda)=> "1"
Temp <= (Consigna-Banda)=> "1"
0 = Señal PI a 0%; 1 = Señal PI mayor que 0%
0 = Señal PI a 0%; 1 = Señal PI mayor que 0%
Valor del sensor de temperatura
0 = No alarma; 1 = Alarma
0 = No alarma; 1 = Alarma
0 = No alarma; 1 = Alarma
Valor de escena
Valor de escena
0-100%
0 = No error; 1 = Circuito abierto
0 = No error; 1 = Cortocircuito
0-100%
Auto, Confort, Standby, Económico, Protección
Valor binario
Soporte técnico:
http://support.zennio.com
54