GENERAL SAFETY PRECAUTIONS

GB
This installation manual is intended for professionally competent per-
sonnel only.
Read the instructions carefully before beginning to install the product.
Incorrect installation may be a source of danger.
Packaging materials (plastic, polystyrene, etc.) must not be allowed to
litter the environment and must be kept out of the reach of children for
whom they may be a source of danger.
Before beginning the installation check that the product is in perfect
condition.
For repairs or replacements of product only original spare parts must
be used. These instruction must be kept and forwarded to all possible
future user of the system.
1.

TECHNICAL DATA

Power supply
Current
Frequency
Output contact
Output power
Protection degree
Temperature
2.
REFERENCES
[1]
Cover
[2]
Terminal block
[3]
Revolving antenna
[4]
Standard lens
[5]
Sensitivity adjustment trimmer
[6]
Dip switch
[7]
Led / Operation indicator
[8]
Spot lens
[9]
Spacer
3.
INSTALLATION AND RUNNING
(Fig. 3) Remove cover [1] by operating with a screw in the appropriate
slit. Firmly secure the radar as it is shown in fi g. 4 so that detection of
overall area opposite the passageway is possible.
Note: Avoid placing objects that can oscillate in the detection area, such
as curtains, signs or plants. Make sure the sensor can not be reached
by rain or snow and is not directed towards fl uorescent lights.
Outside the
detection area
Stand-by
7
Green
Led
Output
relay
(N.O.)
Output
relay
(N.C.)
4.

ELECTRICAL CONNECTIONS

Carry out the connections as it is shown in fi g.5.
5.
DETECTION AREA ADJUSTMENT
5.1
Lens selection
(Fig. 6) Chose the desired detection area form by using the appropriate
lens. With standard lens [4] PASM242 sensors are provided off-the-
shelf.
To select a narrow area, rotate anticlockwise the standard lens [4] and
set DIP4=ON.
When a spot area is selected, remove the standard lens [4] and mount
the spot lens [8] so that the triangles on the revolving antenna and on
the lens meet in the same position.
DITEC S.P.A - IP1803 - PasM242-PasM24W2
12÷24 V=/~
50 mA max with 24 V
24,125 GHz
50 V / 0,3 A max
2mW max
IP44
-20° C / +55°C
Inside the
Outside the
detection area
detection area
Stand-by
Motion
detection
Red
Green
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
5.2
Detection area depth selection
Depth is adjustable by operating on the vertical angle of the adjustable
antenna [3]. In the example of fi gure 7 the installation height is 2.3 m,
the vertical angle is 30° and the sensitivity adjustment trimmer is set
at half.
Note: Make sure the sensor does not detect the moving wing.
5.3
Detection area selection
The example in fi gure 8 shows the detection area adjustment to the left,
which can be obtained by:
a) rotating the revolving antenna with a clockwise movement [3];
b) rotating the standard lens [4] with an anticlockwise movement.
Note: To adjust the detection area to the right, make opposite
movement.
5.4
Sensitivity adjustment
(Fig. 9) Adjust the detection area sensitivity by means of the sensitivity
trimmer [5]:
[Low]
[Sens (Med)] = Medium
[High]
5.5
Dip switch adjustment [6]
DIP1
Only PasM24W2.
Detection mode
DIP2
Only PasM24W2. Tem-
porary two-way mode
DIP3
Relay hold time output
DIP4
Unaffected by en-viron-
mental disturbance
6.
ONE-WAY RADAR PasM24W2
To use radar PasM24W2 in one-way mode, set DIP1=ON and it is advi-
sable to set DIP2=ON to increase the safety of the people detected.
7.

TROUBLESHOOTING

Trouble
Not working
Occasionally not
working
Working by itself There is an object in
Yellow
Yellow
Yellow
Yellow
4
OFF
Two-way
Tem-
T
Disabled
0,5 s
Not disturbed
environment
Cause
Mains voltage
Check voltage
Faulty connection
Check wiring and con-
nector
Dirty cover
Clean cover
S u d d e n
c h a n g e
Check installation condi-
i n d e t e c t i o n a r e a
tion
conditions
Remove the object
the detection area
Water drops on cover Dry cover
The radar subjects to
Firmly secure radar
vibrations
The sensor detects
Adjust detection area ap-
moving wing.
propriately
ON
One-way
Enabled
2 s
Disturbed
environment and
Narrow area
Solution