Electrical lift units
i
3
3
3
3
14
Lift unit for wall
Fault in safety system.
cupboard with
safety plate
cannot be height-
adjusted
Assembly error on
safety plate.
Faulty switches.
The wall cabinet cannot run up or down
if the safety plate is defective.
Check that all wires and plugs are intact
and correctly connected according to the
installation guide.
i
Use measurement device
to detect current. Measure current on
the wire from the safety rail and its plug
(a close function).
- if there is current, the safety device
system is working. The lift unit should now
run out/down. REMEMBER to reset.
- if no current can be detected:
Slacken the screws on the safety plate.
The plate should now move freely. Note
that the plate's freedom to move can be
hindered by dirt or grease.
Check for current once more:
If there is current, the safety device
system is working. If no current can be
detected, see under "Faulty switches".
Check whether one or more of the safety
system contacts is sticking, and if so,
attempt repair . If the problem cannot be
fi xed, replace the contact(s). The safety
system will only work when current can be
detected. REMEMBER to reset.
(ohmmeter)