INSTRUCTIONS FOR USE
Index
Manual control
Programming
dial
DESCRIPTION
The SUPRA time switch can control any electrical installations by means of daily or
weekly programmes.
INSTALLATION
WARNING: Installation and mounting of the electrical apparatus should be carried
out by an authorised installer.
The apparatus is internally protected against interference by a security circuit.
However, certain, especially string magnetic fields may cause alterations in its
operation.
MOUNTING: In a distribution cabinet, fitted with a 35 mm symmetric profile, in
accordance with the EN 50022 standard (DIN Rail), or wall mounted with fixing
supplement incorporated.
CONNECTION: Connection drawing.
SUPRA
M
1
2
3
4
5
PROGRAMMING: Move all the tabs towards the interior of the dial.
Move the tabs that corresponding to the required connection times outwards, in which
contact 2-3 remains closed.
SETTING THE TIME: Turn the time-set control to the right until the indicators mark the
actual time.
MANUAL CONTROL: 3 Positions.
I Permanently on (2-3 closed)
0 Permanently off (2-3 open)
A Automatic operation
TECHNICAL SPECIFICATIONS:
Power supply:
Switching capability:
Own power consumption:
Time-keeping precision:
Time-keeping back-up (QRD, QRS)
Dial type
Minimum operation time
Operating temperature:
Type of protection:
Protection class
DIMENSIONS:
52.5
102
ATTENTIÓN
Those models of time switch with time-keeping back-up include a battery that may be
harmful to the environment if not correctly disposed of. Do not dispose of the device
without first removing the battery and depositing it in a container designed for
recycling these types of battery, or return the product to the factory.
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Teléfono:+ 34 91 5672277;
TIME SWITCH
Hands clock
Time-set button
Terminal cover
Closed (2-3) Open (1-3)
Open (2-3) Closed (1-3)
As indicated on the device
16(4) A /250 V~
0.5 W
± 1 sec./day at 22 ºC
100 hours
Daily: 48 tabs
Weekly: 42 tabs
Daily: 30 minutes
Weekly: 4 hours
-10 ºC to +50 ºC
IP 20 in accordance with EN 60529
II in accordance with EN 60335
under correct mounting conditions.
53
45
A016.29.50039