Electrical Planning
2A
K4
Ref.
Description
K1
Macerator Pump
K3
Macerator Switch
K4
35A Fuse/Breaker
Fig. 2
represents recommended wiring configuration. Other wir-
ing configurations are possible based on your installation.
■
Wiring configuration MUST include internal over-tempera-
ture switch and relay for protection of pump.
■
Pump requires a 12-VDC/35 AMP dedicated circuit with 35
AMP breaker or fuse between main bus or battery.
■
Wire size is dependent on distance between pump and
power source. Actual wire sizes should be calculated ac-
cording to installation.
Electrical System
Wire Gauge Size Chart
If Wire Gauge for distance from
source* is:
12 VOLTS - Install
* Distance measured assumes power
and ground wires
Sani-Con Model 600 - Permanent Storage Mount
Fig. 2
Switch Box Assembly
2B
85
86
0-18 feet
19-32 Feet
(Included)
10 Gauge
8 Gauge
Fig. 3
4
K3
K1
Ref.
Description
2A
Battery
2B
Relay
2C
Over-Temperature Switch (90°C) normally closed
2D
Ground
While the pump is turned on, verify electrical system
AVISO
AVIS
NOTICE
CAUTION
!
by measuring voltage at motor; (must be 12V).
Improper installation may cause damage to motor or
decrease pump efficiency.
The positive and negative wires should be braided to
NOTICE
prevent radio interference during operation.
33-50 feet
6 Gauge
Pump Assembly
2C
18G BLU
18G BLU
2D
Included in product
Circuit Breaker
35 amp