01874
multivoltage supply unit, 230 v~ 50 Hz, for 12-24 v
with mAstER dimmers.
CHARACtERIstICs
• Rated output voltage: 12-24 V
± 10%
• Suitable for LED power and LED SELV modules: 12-24 V
• Supply voltage: 230 V~ 50 Hz;
• Absorption at 230 V~: 125 mA (12 V
• Fuse with high breaking capacity type 1 A incorporated
• jumper for selecting the output voltage
• Terminals:
- 2 for power supply (L phase, N neutral)
- 1 for synchronism (S)
- 2 for led module output (+, -)
• max. output current: 1,7 A (12 V
), 1 A (24 V
• maximum load: 20 W (12 V
), 24 W (24 V
• PfC active:
- Power factor = 0,92 (12 V
, 20 W)
- Power factor = 0,90 (24V
, 24 W)
• Max. dissipated power: 6 W a 12 – 24 V
• Yield η: 77% (12 V
20 W), 82% (24 V
• Consumption in standby: < 0.5 W
• Operating temperature ta: -5 °C - +45 °C (indoor)
• Appliances of class II
• Max number of Power supplies:
- with circuit breaker C10: max 7;
- with circuit breaker C16: max 12.
• Power supply for incorporation IP20 for internal use;
• Galvanic isolation between primary and secondary: 4 kVrms;
• Adjustable dimmer:
• with Vimar universal master dimmer configured for Leading Edge (art. 20135/19135/16559/14135
- art. 20136/ 19136/16603/14136). ON/OFF and brightness adjustment from 0 to 100% (con-
sult the instructions of the 1M rocker and rotary universal master dimmer with incorporated
button). Do not connect to a conventional phase cutter dimmer.
- with on/off switch between the phase and dimmered input. ON/OFF control at 100% brightnes
of the power/LED module
• Max 10 power supplies connected to a single master dimmer (see also max number of power
supplies with circuit breaker)
• Cable length from master dimmer/switch to last power supply: max 100 m
• Cable length for led modules: 10 m with cables section 1.5 mm
• Supplied with terminal protection and cable clamps
• Opposite input and output terminals
• Cable section:
- Primary: 0,75 mm
– 1,5 mm
(rigid cables); 0,75 mm
2
2
- Secondary (LED terminals): 0,5 mm
2
– 1,5 mm
• Cable clamp on primary and secondary for cable diameters:
- Primary: min 4 mm- max 8 mm
- Secondary: min 4 mm- max 8 mm
• Screw fixing for power supply
• Protections: Thermal (auto-off reversible), Short circuit, Overloads
• Max. temperature of tc case: 80 °C
• Size (l x w x h): 224 mm x 60 mm x 36 mm
ConnECtIons
The typical power supply installation requires the use of the stand-alone Vimar universal
master dimmer in the configuration described in fig. 1.
The stand-alone Vimar master dimmers which can be used to control the dimmerable LED
electronic power supply are:
• 1M universal rocker master dimmer: art. art. 20135-19135-16559-14135;
• 1M universal rotary master dimmer + button: art. art. 20136-19136-16603-14136.
• The dimmer connection should be made together with a fuse carrier with a fuse with a high breaking
capacity type F2.5AH250V as shown in the diagrams..
L
20135-20136
19135-19136
L
16559-16603
14135-14136
P
20416
19416
16460
14416
L
N
20008
19008
L
16080
S
N
S
14008
N
N
Fig. 1. Diagram of electronic power supply 01874 + universal master dimmer connections.
Viale Vicenza, 14 - 36063 Marostica VI Italy
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188 - Fax (Export) +39 0424 488 709
www.vimar.com
LED lamps, controllable
20 W) ,145 mA (24 V
24 W)
)
)
24 W)
2
– 1 mm
(flexible cables)
2
2
2
(rigid cables); 0,5 mm
2
– 1 mm
2
(flexible cables)
LED module/ LED strip
01874
! Important: With the art. 01874 the LED modules must be connected only in parallel.
The LED dimmerable electronic power supply can also be controlled by a switch between the
phase and the controlled input (fig. 2). In this case it is only possible to switch ON/OFF at maxi-
mum brightness of the LED module connected to the power supply.
L
switch
L
L
N
S
S
N
N
Fig. 2. Diagram of LED dimmerable power supply 01874 + ON/OFF switch connections.
Select the rated output voltage 12-24 V
necting the power supply to the mains 230V~.
24 V
12 V
+
-
Fig. 3. Position of the jumpers for selecting the output voltage 24 V

InstALLAtIon RULEs

Installation should be carried out in compliance with the current regulations regarding the installa-
tion of electrical systems in the country where the products are installed. Ensure clearance around
the appliance so there is sufficient ventilation.
There must be no dripping or splashes of water on the appliance.
01874
Ta: 45°C max
01875
A
A
01874
01874
A ≥ 25 mm; B ≥ 100 mm
Fig. 4. Minimum clearance between the LED dimmerable electronic power supply 01874 and the lights
and/or external walls
for all details on possible installation architectures, please refer to sI-Connection diagrams
for the relevant item code at www.vimar.com -> Products -> Product catalogue.

stAnDARD ComPLIAnCE

LV directive
EMC directive
Standards EN 61347-2-13, EN 62384, EN 61547, EN 61000-3-2, EN 61000-3-3, EN 55015.
01874
LED module/ LED strip
using the jumpers on the secondary side before con-
To set the voltage to 24 V
nominal output, set
the jumpers as shown.
To set the 12 V
nominal output voltage, place
the jumper up at the labeled 12 V.
LED module/strip output terminals
.
B
LED module/
LED strip

Publicidad

loading