1
UNPACKING
• This luminaire has been properly packed so that
no parts should have been damaged during transit.
• Inspect to confirm.
2
HANDLING
• Damage may occur if luminaire is improperly
handled outside of pack.
• Do not impact or stack luminaire after removal
from packaging.
3
OUTLET BOX MOUNTING
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
• The luminaire can be mounted to a suitable recessed
mounted outlet box (3 1/2-in. or 4-in. octagonal).
• The Mounting Bracket may be attached to the outlet
box with two 10-24 screws (not provided),
approximately 1" (25mm) long.
• An alternate method of mounting the Mounting
Bracket over a recessed-mounted outlet box is to
position back cover over the box and securely mount
with lag bolts (not provided) through the holes
provided in the back cover (see Figure 1).
FIGURE 1
4
MOUNTING
• Remove the back Mounting Bracket by loosening
the screws on the bottom of the unit and sliding
the Mounting Bracket up and out of the slots and
removing the electrical coverplate. (see Figure 2).
FIGURE 2
• Attach the Mounting Bracket to the wall or outlet
using the holes in the cover as a drill template.
Alternately, the mounting diagram in these
instructions may be used as a drill template
(see Figure 3).
• Connect electrical wires to the fixture by pulling
wires from the outlet box into Electrical Cavity.
Connect wire on unit to wires from outlet box.
IMPORTANT: Connect ground lead to terminal
provided.
• Make all electrical connections in accordance with
the National Electrical Code and any applicable local
code requirements
• Slide fixture onto Mounting Bracket and Re-attach
electrical coverplate with screws below the unit.
• A gasket is provided on the back of the unit to provide
water and dust protection when mounting to smooth
surfaces. To maintain UL wet location protection of
the unit on textured surfaces (block, brick, etc), caulk the
back of housing with generic non-hardening sealant
(not provided) across the top, bottom and both sides.
External Dimming Control (If Applicable):
• Gray Lead = 0VDC (-)
• Violet Lead = Up To 10VDC (+)
Dimming Input/Output
Control Voltage
1
Nominal Input Wattage
Nominal Lumen Output
1
Linear Transition between Low and High
Component and system tolerance may affect the
2
end point levels and linearity of transition
PE Dimming Control (If Applicable):
• No external connections for Dimming are required
when the GE Dimming PE Control and GE Dimming
PE Receptacle is used.
• All dimming control connections will be made
between the Dimming PE and Luminaire through the
included PE Receptacle.
• Refer to instructions included with GE Dimming PE
Control regarding appropriate settings for dimming control.
Occupancy Sensor (optional):
• The programmable occupancy sensor is shipped with
a default program which may be modified using the
WattStopper
FSIR-100 wireless IR configuration tool
®
(sold separately).
Low (0-1.25V) High(7.5-10V)
2
10% of Max
100%
2

Publicidad