Conversion Instructions (continued)
16
Insert Heat Plates and Cooking Grids
18
Perform a Leak Check
If you smell gas -
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or your
fire department.
1. Do NOT operate if gas leak is present. Gas leaks may cause a fire or explosion.
2. You must follow all leak-checking procedures before operating. To prevent fire or explosion hazard
when testing for a leak:
a. Always perform leak test before lighting the grill and each time the LP gas tank or natural gas
line is connected.
b. No smoking. Do not use or permit sources of ignition in the area while conducting a leak test.
c. Conduct the leak test outdoors in a well-ventilated area.
d. Do NOT use matches, lighters or a flame to check for leaks.
e. Do NOT use grills until any and all leaks are corrected.
If you are unable to stop a leak, disconnect the LP or Natural gas supply. Call a gas appliance
serviceman.
Natural Gas Conversion Instructions – VFK1000W
Model No. GBC1273W / BH12-101-001-02
17
Insert Warming Rack