Display during Operation
Operating mode
mA
mA
Paragraph 3 – Proportional to External Impulses (multiplication)
Programming
PROG
Configuration
Pump Funtions
-­‐
+
Pump
Functions
Multiply (1:n)
Multiply (1:n)
-­‐
n
4
Multiply (1:n)
-­‐
Timeout
0s
Multiply (1:n)
Memory
-­‐
Off
Display during Operation
Operating mode
1:n = impulse
multiplication
Paragraph 4 – Proportional to External Impulses (division)
Programming
PROG
Configuration
Pump Funtions
-­‐
+
Pump
Functions
Divide (n:1)
Divide (n:1)
n
-­‐
4
EM00136204
(default: 4-20)
4-20
Stop
P100%
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
The pump doses in proportion to an external signal (i.e.: impulse launch
counter). With every signal received, the pump makes the programmed
"n" number of strikes. The pump automatically sets the dosage frequency,
adapting it to the time that passes between two successive signals. It is
possible to set the time (timeout) in seconds, beyond which the pump
resets the interval count in order to avoid dosages over excessively long
times. The pump has a memory function, which signals the reception of a
signal during dosage. If set to Off, it merely sends a signal, if set to On it
-­‐
sends a signal and memorises the impulses, then executes them when it
+
has finished receiving signals.
-­‐
The value of "n" can be modified during operation, by pressing the
+
-­‐
+
to decrease it.
Memory
function
status
1:n
M
1
M
M
Stop
0
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
The pump doses in proportion to an external signal (i.e.: impulse launch
counter). At every "n" signals, the pump makes a strike. You can set the
value of "n" during programming. By programming the value of "n" you set
the maximum dosage %. This value can be modified during operation, by
pressing the
-­‐
the
+
Programmed value
Programmed interval value
Current dosage value
(depends on the selected unit
of measurement)
Percentage, Frequency,
l/h, Gph, ml/m
keys at the same time to increase the flow, or the
Programmed
value of n
Current dosage value
Displays stroke
countdown
keys to decrease it.
rev. 2.1
Display during Setting (MODE key)
Operating mode
Displays the Low and High
value in sequence
Low
0.0 mA
Current dosage value
Makes it possible to modify the
maximum dosage value by pressing
the + or – buttons at the same time
Operation
Display during Setting (MODE key)
Displays programmed
timeout
Timeout
0s
Current dosage value
Displays the value of n. This
can be modified by pressing
the + or – keys at the same
time
Operation
keys at the same time to increase the flow, or
Input mA
value
0
P100%
keys
n
1
4