Ambient temperature:
-20 ... +65 °C at 10 ... 26 V DC
-20 ... +55 °C at >26 ... 30 V DC
Storage temperature:
Altitude:
EMC:
Noise emission
Noise immunity
Housing:
Weight:
Protection:
Cleaning:
6. Terminal assignment
1 10 ... 30 V DC
2 0 V GND
3 INP
4 –
5 Reset
7. Ordering code
6.520.012.3X0
8. Delivery includes:
1 Digital display
1 Panel mounting clip
1 Bezel for screw mounting, panel cut out
50 x 25 mm
1 Bezel for clip mounting, panel cut out
50 x 25 mm
1 Seal
1 Multilingual operating instructions
* at maximum frequency square wave pulses 1:1
–25 ... +70 °C
to 2000 m
EN 55 011 Class B
EN 61 000-6-2
For front panel mounting
48 x 24 mm acc. to
DIN 43700,
RAL 7021, dark grey
appr. 50 g
IP 65 (front)
The front of the units is to
be cleaned only with a soft
wet (water!) cloth.
Input sensitivity
0 = Standard sensitivity
A = 4 ... 30 V DC level
3