OPERATION
The electronic control unit has been designed for programming itself so as to be ready for
use as soon as it is connected to the power supply.
SELF-LEARNING AND AUTOMATIC CLOSURE TIME ADJUSTMENT (Fig. 13)
CAUTION: the self-learning procedure requires the connection of all the safety
devices; if one or more safety devices are not used, jumper the corresponding
input to terminal 16.
Press the MEMO button; the red led will come on and the door will be automatically closed
until the back stop. After 2 seconds, the door will open until the back stop and the red led
will go off (the entire procedure of stop acquisition is performed at low speed).
From this moment, the counting in seconds for automatic closure begins; after the
desired time, press the OPEN button. The door will be closed getting out of programming
automatically, calculating speed and deceleration to be implemented during the manoeuvre.
NB. The automatic closure time is counted by the operator and varies from 0 to 90 seconds,
or shown on the programmer's display (optional cod. ACG9419).
DAY / NIGHT SELECTOR OPERATION (Fig. 14)
With the DAY / NIGHT selector (optional cod. ACG9426), the SLIDER automatic sliding door
can operate in two basic configurations.
Connect the selector to terminals 16 (COM), 23 (INT.I) of the ONE SLIDER electronic control
unit.
- ON POSITION SELECTOR (DAY)
By turning the key to position ON
(automatic), the automation accepts the opening
orders from the external activation sensors and/or from an external button connected
to terminals 16 (COM) and 22 (OPEN).
- OFF POSITION SELECTOR (NIGHT)
By turning the key to position OFF
locked by the electromechanical locking device (if installed).
The automation accepts an opening order only from the external button connected to
terminals 16 (COM) and 22 (OPEN).
CAUTION: The DAY / NIGHT function selector has priority over any other
accessory connected to the automation.
For a correct operation and constant battery recharge, the automation must
remain powered and with the batteries connected even at night.
(night stop), the automation remains closed and
TECHNICAL DATA
Power supply
Fuse
Accessories power supply
Motor output
Electric lock voltage
Battery charger
Temperatures
Degree of protection
COM
NO
NC
35
LED MEMO
MEMO
OPEN
125 / 230 V.a.c. 50/60Hz
F1 1,6 A.T Sec. 22 V.a.c. 180 VA
24 V.d.c. I Max 0.5 A
Protection fuse PTC
24 V.d.c. Max Pow. 100 VA
Protection fuse F2 8 A T
12 V.d.c. V. mant. 6 V.d.c. with Pid Control
27,5 V.d.c. I Max 0,5 A - Protection fuse PTC
-20°C / +55°C
IP20
DAY / NIGHT SELECTOR
code ACG9425 built-in
code ACG9426 to wall