ALWAYS make sure all electrical work is done by qualified persons in accordance with local
building and electrical codes, Section 62 of the Canadian Electrical Code (CEC)
Part I, and the National Electrical Code (NEC), especially Article 424.
ALWAYS use copper only as supply conductors to the thermostat. Do not use aluminum.
ALWAYS seek help if a problem arises. If ever in doubt about the correct installation procedure
to follow, or if the product appears to be damaged, the factory must be called before
proceeding with the installation.
Installation must be performed by qualified personnel, in accordance with local codes and
standards. A licensed electrician is recommended.
Phase 1 - Preparations
• Before installing Mat, make sure to fully inspect the products and carefully plan the site.
Items Needed
Materials:
• SunStat thermostat control with floor sensor
• Control electrical box (UL Listed, extra deep, see control instructions for size and type required)
• Junction electrical box (if required, see Step 2.2)
• Flexible or rigid conduit (if required, see Step 2.4, must be UL Listed and proper size)
• 12-gauge or 14-gauge electrical wiring cable (consult local code)
• Wire nuts (if a junction electrical box is required, see Step 2.2, must be UL Listed and proper size)
• Nail plate
Tools:
• Digital multi-meter for ohms testing; must read up to 20,000 ohms to measure sensor
• Drill with 1/2" & 3/4" bits
• Hammer and chisel
• Hot glue gun and hot glue (craft grade)
• Wire strippers
• Phillips screwdriver
• Fish tape
• Hole saw
• Floor covering installation tools
Floor sensor is
included in the
SunStat thermostat
packaging. This must
be installed in the
floor with the mat.
5 of 96