Descargar Imprimir esta página

Maxon 287369-01 Manual De Instrucciones página 7

Ocultar thumbs Ver también para 287369-01:

Publicidad

Idiomas disponibles

Idiomas disponibles

LIFT CORPORATION Sht. 7 of 42 DSG#
12. Connect #6 face seal connector
and elbow (Kit items) to pump port
A, as shown in FIG. 7-1. Connect
#6 face seal connector (Kit item)
to open side of needle valve (FIG.
7-1).
13. Next, connect needle valve (Kit item) to
elbow on pump port 'A' (FIG. 7-1). Do not
tighten connectors until later in this proce-
dure.
14. Connect SAE #6 fitting (Kit item), flow valve,
and branch tee (Kit item) to the bulkhead tee
(FIG. 7-2). Do not tighten connectors until later
in this procedure.
© MAXON Lift Corp. 2017
CONNECTOR,
FACE SEAL #6
(P/N 905173)
CONNECTING ELBOW, NEEDLE VALVE
CONNECTING HIGH PRESSURE FLOW
M-13-07
Rev. - Date: 07/12/17
CONNECTOR,
FACE SEAL #6
(P/N 905173)
& CONNECTORS
FIG. 7-1
VALVE & FITTINGS
FIG. 7-2

Publicidad

loading