3.5.5 Parameter error
If, after the machine switching on, the following message appears on the display:
some incongruous values have been found in the machine parameters.
Contact the Service for further information.
It is anyway possible to restart the machine with the standard settings:
Press contemporaneously the 3 and 7 keys for 5 seconds: the device restores the default values
and restarts automatically. While holding the keys, the display shows the menu of figure 18 and
indicates that the standard values are being setting.
3.6 OPERATION INTERRUPTION
If, with tension available, all displays remain off, it means that electrical supply does not reach
the main board, or this latter is damaged.
Possible causes:
A) Overtension and/or supply fuse failure. Open the fuse housing next to the supply plug, take
out the spare fuse and replace the damaged one.
B) Damage to the actuators board or the main board. Contact the Service.
DOMIX 45 A – 2600111 – 11.09.2001
r A M
d
E
F
Figure -17
d
o
M
A
U
t
Figure –18
8