parameter.  For  example,  when  setting  the  temperature,  increase  the  set  temperature  value. 
When  setting  the  parameter  value,  press  and  hold  the  up  button  for  a  long  time  and  the 
parameter will increase rapidly. Under normal conditions, press and hold the key for 3 seconds to 
import the data of 12 months into the U disk. 
h.
is the button for set/mute, when there is no alarm state and the key is locked, press 
,Displaying  ambient  temperature  for  5  seconds  then  return  to  normal  display;  In  the 
unlocked state, press
high/low temperature alarm, door open alarm, sensor fault alarm, etc.), in the locked state, first 
time press 
, Buzzer stops tweeting, 5 seconds after showing ambient temperature, return 
to normal display(The key mute is only to turn off the buzzer of this abnormal state alarm. If the 
fault  is  eliminated,  the  buzzer  will  continue  to  alarm  when  the  next  alarm  occurs),  press 
again, buzzer beeps, after the ambient temperature is displayed for 5 seconds, the cabinet 
temperature and alarm status are restored. When the press is under unlocked state, 
be used as a set button. 
In the unlock state, in the parameter setting mode, press this key to display the value and 
the parameter name. If the pressed time is longer than 3 seconds, the setting is saved and the 
normal interface is returned. 
i.
USB data export 
    Automatic export: After the U disk is connected to USB interface, the data of this month and last 
month  will  generate  PDF  file  in  U  disk,  the  buzzer  will  beep  once  after  the  data  transmission  is 
completed. 
Manually  export:  If  the  button  is  under  unlocked  state,  after  connecting  U  disk  well  and  buzzer 
alarm for one time, press upper button for 3 seconds, digital tube display "d01", Press the up button 
or  down  button  to  adjust  "d00~d12",  press
generates this file (d00) or generates the data recorded in the previous month (1‐12). 
      Attention:  When  the  digital  tube  alarm  flashes  to  indicate  "LoF",  the  recorder  is  not  started.  if 
you  press  the  key 
recorder starts. 
 
for 3 seconds, enter into the user menu. When buzzer alarm (including 
  and 
for  3  seconds  at  the  same  time,  "LoF"  disappears  and  the 
,  The  U  disk  internally  generates  a  PDF  file  that 
  can 