General Safety Information - Wayne WCP85 Manual De Instrucciones De Operación

Unidad de condensación
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation and Instruction Manual
General Safety
Information
(continued)
To reduce the risk of electric shock, the
motor must be securely and
adequately grounded. This can be
ac com plished by inserting plug directly
into a properly installed and grounded
3-prong, grounding-type re cep ta cle (as
shown in Figure 1).
Risk of electrical
shock! This pump is
supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electric shock.
Grounding
Blade
Figure 1 - Grounding
Never cut off the round grounding
prong. Cutting the cord or prong will
void the warranty and make the pump
inoperable.
Where a 2-prong wall receptacle is
encountered, it must be replaced with
a properly grounded 3-prong re cep ta-
cle installed in accordance with the
NEC and local codes and ordinances.
12. All wiring should be performed by a
qualified elec tri cian.
13. It is strongly recommended that this
unit is plugged into a Ground Fault
Circuit Interrupter (GFCI). Con sult a
local electrician for installation and
availability.
14. Protect electrical cord from sharp
objects, hot sur fac es, oil, and
chemicals. Avoid kinking the cord.
Re place or repair damaged or worn
cords im me di ate ly. Use wire of
adequate size to minimize voltage
drop at the motor.
15. Do not handle a pump or
pump motor with wet
hands or when standing
on a wet or damp
surface, or in water.
16. Do not use an extension cord.
www.waynepumps.com
has been turned off. If the shut-off box is
in basement, call the electric company to
shut-off service to the house, or call the
local fire department for instructions.
Remove pump and repair or replace.
Failure to follow this warning can result
in fatal electrical shock.
Installation
damage and/or personal injury might
result from an inoperative or leaking
pump due to power outages, discharge
line blockage or any other reason, use
a backup system(s).
STEP 1: INSTALLATION OF PIPE
A. Insert the discharge pipe or pipe
nipple into the 3/8" ID plastic tube.
TEST
RESET
mounting position for service, always
disconnect electrical power to pump
and control switch. For any work on
pump or switch, always unplug the
power cord. Do not just turn off circuit
break er or unscrew fuse.
STEP 2: MOUNTING CONDENSATE
UNIT
A. Position the pump below the
evaporator drain and/or furnace
drain.
B. The pump can be installed to the
wall or side of the appliance using
the two mounting brackets. Refer to
Figure 2.
High efficiency
gas furnace
Figure 2 - Mounting location
Do not walk on wet
STEP 3: INSTALLATION OF
area until all power
CONDENSATE DRAIN LINES
A. To prevent pipe blockage in the
B. Plumb flexible tube or pipe from
In any installation
where property
STEP 4: INSTALLATION OF
DISCHARGE LINE
NOTE: Use 3/8" I.D. (max.) flexible
tubing. A hose clamp is recommended
(not provided).
A. Extend discharge pipe from barbed
Before removing
pump from its
B. From this point, direct the discharge
NOTE: Construct an inverted "U" (see
Figure 5) at the highest point of
discharge line if a continuous
downward slope is not possible.
Exercise care not to kink or "pinch off"
the flow of condensate liquid.
2
reservoir, modify the end of pipe or
tubing as illustrated in Figure 3.
the condensate drain, and from the
furnace drain (if applicable), to the
inlet holes on the pump. Refer to
Figure 4.
check valve to the highest point
possible. Refer to Figure 5.
line to the location of the drainage
source. Maintain a continuous
downward slope.
GFCI Outlet
Mounting
brackets
6 1/2" above floor