ABB-Welcome
6
Mounting/Installation
Pos : 34 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Fü r alle Dokumente <--)/Warnhinweis e/Sic herheit - Ni eders pannungs- und 230 V-Leitungen @ 18\mod_1302617821491_15.doc x @ 103465 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electric voltage of 100-240 V.
–
Low-voltage and 240 V cables must not be installed together in a flush-mounted socket!
In case of a short-circuit there is the danger of a 230 V load on the low-voltage line.
Pos : 35 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Fü r alle Dokumente <--)/Warnhinweis e/Sic herheit - Vorgesc haltete Sicherung abschalten @ 20\mod_1326441711467_15.doc x @ 137043 @ @ 1
Warning
Electric voltage!
The upstream fuse must be disconnected when working on the lighting system.
Pos : 36 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Sic herheit (--> Fü r alle Dokumente <--)/Warnhinweis e/Sic herheit - F ac hkenntniss e @ 18\mod_1302774384017_15.doc x @ 103564 @ 2 @ 1
6.1
Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
•
Incorrect installation endangers your life and that of the user of the electrical system.
•
Incorrect installation can cause serious damage to property, such as a fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
•
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1.
Disconnect the power;
2.
Secure against being reconnected;
3.
Ensure there is no voltage;
4.
Connect to earth;
5.
Cover or barricade adjacent live parts.
•
Use suitable personal protective clothing.
•
Use only suitable tools and measuring devices.
•
Check the type of supply network (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos : 37 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Übersc hriften (--> Fü r alle D okumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.doc x @ 103424 @ 2 @ 1
6.2
Mounting
Pos : 38 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Montage/alle Geräte/Montage - U P-Dosen - D IN 49073- 1 oder geeignetes Aufputzgehaeus e - Ohne D oc variabl e @ 20\mod_1325766034453_15.doc x @ 136593 @ @ 1
The device must only be installed on mounting rails according to DIN EN 50022.
6.3
System security
Avoid misuse by intruders and configure your telephone system in a way that the telephone gateway cannot
directly be called from an external telephone. This will prevent unauthori zed access of intruders.
If it is necessary to have external access to the gateway, please activate the indoor station PIN. (See page 9.)
Pos : 39 /Busc h-J aeg er (Neustr uktur)/Modul- Struktur /Online-Dokumentati on/Steuermodul e - Onli ne-D okumentation (--> F ü r all e D okumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268898668093_0.doc x @ 52149 @ @ 1
— 8 —