WARNING: Turn power off at the fuse
or circuit breaker before wiring.
INSTALLING SENSOR
1. Remove the decorative cover plate (secured by
two small screws).
Figure 2 - Removing Decorative Cover Plate
Mode
Selection
Switch
Figure 3 - Connecting Electrical Leads of Sensor
OFF
AUTO
ON
1. Remove existing wall switch from junction
box.
2. Connect electrical leads of sensor as shown in
Figure 3. Before installing sensor into junction
box, make sure there is no wire exposed at
each connection.
3. Mount sensor into junction box using two large
mounting screws provided.
4. Turn the power back on at the circuit breaker.
5. Set mode selection switch to theAUTO position.
When unit stabilizes (about 1 minute), the sensor
is ready to detect motion. If sensor detects motion,
the lights will turn on. The lights will turn off 5
minutes after motion is no longer detected.
Note: If lights do not turn on when motion is
detected after the warm up period, the switch is
wired incorrectly. Turn the power off at circuit
breaker and switch the black and brown sensor
wires. Test again.
IMPORTANT: The switch will not work
unless the ground wire is connected.
CAUTION: Do NOT connect the motion
switch to house NEUTRAL (white wire).
To Lighting Load
Brown
Lighting Load
Black
2
Typical Installation
Neutral
Return
Green ground wire to
junction box screw or
grounding wire.
Line
"Hot"
200069-01