Installation
7) Insert pivot rod (N12) into drain
body (N7) against gasket (N8)
and inner seat (N10). Install outer
seat (N11) against pivot ball and
secure assembly by tightening
retaining nut (N13).
N12
N8
N11
N7
N10
Maintenance
1) Remove cap screw (H), cap (B),
handle (A), dome (C) and spring (D)
from faucet. Remove compression
nut (F) using 1 1/8" deep socket.
B
D
2
A
3
C
Finish is spotting.
Symmons Industries, Inc.
Copyright © 2019 Symmons Industries, Inc.
8) Insert lift rod (E) into back of
faucet. From below, attach clevis
strap (N15) to lift rod (E). Tighten
thumb screw (N16) to secure.
N13
2
2) Remove cartridge (G) and inspect
for debris. Replace if necessary.
Using an angled mini pick,
remove flow regulator (I) and
inspect for debris. Replace if
necessary.
F
H

Troubleshooting Chart

Elements in water supply may cause
water staining on finish.
31 Brooks Drive
symmons.com
E
1
N16
N15
G
1
I
2
Braintree, MA 02184
Phone: (800) 796-6667
gethelp@symmons.com
9) With stopper (N1) closed, insert
pivot rod (N12) into clevis strap
(N15) at desired height. Secure
with spring clip (N14).
N15
N1
N14
N12
N14
3) Install flow regulator and cartridge
following steps 1 & 2 in reverse.
Clean finished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.