PRE-SERVICE INSTRUCTIONS
1. Close both valves on the manifold gauge set by turning the High and Low knobs clockwise.
2. The gauges are correctly calibrated at the factory before shipment. If calibration is required,
remove the lens and insert a straight blade screwdriver into the adjusting screw on the gauge
face.
3. Connect the (Red) hose to the High port and the (Blue) hose to the Low port on the manifold
gauge.
TESTING AND CHARGING
To properly diagnose the problem in the R/AC system, first check the system's overall perfor-
mance. This includes monitoring the system's pressure as well as leak testing. Your manifold
gauge set will give accurate readings of your system's pressure.
NOTE: Be sure that the hand valves on the manifold gauge set are in the closed position.
Always wear gloves and safety goggles when working with refrigerant.
1. Remove the protective caps from the system ports. Check for leaks at the ports.
2. Connect the Low Side service hose (Blue) to the suction side of the compressor. Connect the
High Side service hose (Red) to the discharge side of the compressor.
3. If using adapters, make sure that they are fully tightened and piercing the access valve. Failure
to properly access the valve core will prohibit refrigerant flow.
IMPORTANT NOTES
• A system that has been opened or one that is found to be excessively low on refrigerant
pressure as a result of a leak, must be fully evacuated by means of recycling and deep
vacuum.
• A system that has been evacuated must be repaired, leak tested and evacuated again to 29"
Hg. before charging.
• If charging on the liquid or High Side, use only the High Side valve on the manifold gauge set.
Make sure the Low Side valve is closed.
• After charging, test the system by turning on the engine and running the A/C with both valves
closed on the manifold.
• After testing, disconnect the hoses from the system and make sure to use a recovery/recycling
machine to evacuate any refrigerant remaining in the hoses or manifold.