SAFETY CONSIDERATIONS
Caution: Strong magnetic field.
The Sentinel Eliminator® is a vessel under pressure containing a hot fluid. It is
recommended that it is installed by a suitably qualified person.
Always ensure that the system has cooled before attempting installation. Check
very carefully for any leaks after fitting the filter and pressurising the system.
The T-piece collar must be hand tightened only; do not attempt to use a tool as
this could damage the seal.
Care should be taken when flushing a hot system.
SYSTEM DESIGN
The Sentinel Eliminator is suitable for use on all wet central heating systems.
The cyclones are not optimsed for flow rates above 25 litres per minute.
The Sentinel Eliminator is rigorously tested to confirm it meets the temperature
and pressure requirements of a typical domestic system.
The filter should be preferably mounted on the boiler return pipe only.
The Sentinel Eliminator is compatible with the full Sentinel chemical range.
For full system protection it is recommended that the system be cleaned prior
to fitting the filter and Sentinel X100 Inhibitor be added to prevent corrosion
and the formation of limescale.
MOUNTING CONSIDERATIONS
Before fitting the filter, ensure that adequate clearance is available, including
the vertical space required to drain the filter during servicing.
The filter can be fitted to either horizontal or vertical pipe-work by rotating the
T-piece. Regardless of the pipe-work orientation, the filter body must be orientated
vertically. IMPORTANT: Ensure that T-piece is aligned to the direction of flow.