Warning! Detail B (fixing bracket to the ceiling - Fig. 1) is
equipped with a conductor (yellow-green) that must be
connected to the earth of the domestic electrical plant.
Fig. 4
ATTENTION! Be particularly careful about positioning
the excess cable. Failure to observe this indication could
cause grave damage to the apparatus and/or an electric
shock to the user or the installer. For further details see Fig.
8-15
Warining! Changing the interconnection cable must be
carried out by the authorised technical assistance service.
Mounting
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Additional Installation Specifications:
Use only the fixing screws supplied with the product for
installation.
Use the correct length screws which are identified in the
Installation Guide
WARNING! Failure to install the screws or fixing device in
accordance with these instructions may result in electrical
hazards.
Description of the hood
Fig. 1
A. Cover
B. Support to the ceiling bracket
C. Regulators of the tie-rods of the hood
D. Decorative cover
E. Box for connecting to the domestic power network
F. Interconnection cable
G. Halogen bulb
H. Active carbon filter
I. Metal anti-fat filter
Operation
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
A. on/off light switch
B. on/off aspiration switch and minimum power selection
B+C. medium power selection aspiration switch
B+D. maximum power selection aspiration switch
Maintenance
ATTENTION! Before performing any maintenance operation,
isolate the hood from the electrical supply by switching off at
the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and
socket, then the plug must be removed from the socket.
Cleaning
The cooker hood should be cleaned regularly (at least with the
same frequency with which you carry out maintenance of the
fat filters) internally and externally. Clean using the cloth
dampened with neutral liquid detergent. Do not use abrasive
products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning
recommendations of the cooker hood and replacement of the
filters may cause fire risks.
Therefore, we recommend observing these instructions.
The manufacturer declines all responsibility for any damage to
the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease filter
Traps cooking grease particles.
This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
19