9. Maintenance and service
Please note:
The milling spindle must not be cleaned with compressed air!
Depending on the degree of contamination, the chuck must be cleaned and degreased (see section 8) from
time to time.
10. Malfunctions
If the milling spindle is overloaded or blocked, the unit switches off automatically (for safety reasons). The
unit can be started again by switching "off" and "on" (5.17).
If the power decreases or the motor does not run steadily, the unit should be sent to bredent.
If the spindle does not work:
- are the power supply/voltage data in accordance with the data on the typeplate?
- has the power plug been plugged in?
- has the cable of the handpiece been connected correctly to the control unit?
- power switch (5.17) must be set to "on".
- turn rotary knob (5.19) to adjust the recommended speed.
- clamping lever (5.7) must be moved to the left side.
11. Technical data
Width:
Depth:
Height:
Weight:
Speed:
Voltage:
Ampere:
Wattage:
hertz:
12. Accessories
The following accessories are available for the milling unit BF2:
Milling base
Tap handwheel
Model support
Chuck, 3 mm
Transfer device (oder: Transfer jig) REF 360 0116 3
Brenometer surveying system
13 Additional information
These instructions for use are based on state-of-the-art methods and equipment and our own experience.
The product may only be used for the indication described under item 2. The user himself is responsible for
processing the product. Liability for incorrect results shall be excluded since the manufacturer does not have
any influence on further processing. Any occurring claims for damages may only be made up to the value of
our products.
10
250 mm
370 mm
510 mm
19 kg
500 - 30,000 min
-1
100 - 115 V / 200 - 240 V
2 x 2.0 A
80 W
50 – 60 hz
BF1 REF 140 0089 3
BF1 REF 330 0115 4
REF 730 0017 0
REF 730 0015 3
REF 310 0000 2