2.1) Electrical connections

!
WARNING: a reverser switch must be used during the programming operations to enable the simultaneous activation
of the electrical UP phase and electrical DOWN phase. Alternatively, the special MA 2001 control unit can be used for
the programming operations, though it must later be replaced with the appropriate reverser switch.
!
WARNING: for motor connections, an omnipolar disconnecting device with a 3-mm minimum distance between con-
tacts must be provided for disconnection from the mains power supply (disconnecting switch or plug and socket, etc.).
!
WARNING: carefully follow all the connection instructions. If you have any doubts do not make experiments but con-
sult the relevant technical specifications which are also available on the web site „www.stobag.com".
An incorrect connection may be dangerous and cause damage to the system.
The cable used for the electrical connections of the MOVENO DWIRE-V motors has 4 wires: electrical UP phase, electrical DOWN phase,
Common wire (usually connected to the Neutral) and Earth (unipotential protection connection). From an electrical viewpoint MOVENO DWIRE-
V is controlled like any normal motor equipped with electromechanical limit switches (fig.6); on the other hand, MOVENO DWIRE-V features
an electronic limit switch system programmed to stop the motor at pre-established positions. The connection devices are not supplied with
the product.
Note: during the installation and adjustment operations, when no final electrical connections exist, the motor can be controlled using the "MA
2001" unit.
M1
M2
~
~
1 2
3
PE
1 2
3
PE
1 2
1 2
3
PE
1 2
3
PE
1 2
1
2
3
1 2 3
4x1.5mm
L
N
PE
2
3x1.5mm
LNPE
(230VAC / 50Hz)
The motor's electrical "up" and "down" phases are perfectly interchangeable, since the former causes the motor to rotate in one direction, the
latter in the opposite direction. The up and down movements are determined by the side from which the motor is inserted in the winding tube.
To change the direction of rotation, switch the brown and black conductors.
Except for the limit switch programming operations, it is possible to connect multiple MOVENO DWIRE-V motors in parallel so
as to utilise a single reverser switch.
3) Adjustments
The MOVENO DWIRE-V series tubular motors are equipped with an
electronic limit switch that interrupts the power supply when the awn-
ing or shutter reaches the opening or closing limit. These two limits
must be programmed into the memory after the motor has been
installed and the shutter/awning mounted. The motor can still be
commanded even if these two travel limits, (hereinafter referred to as
"position 0" and "position 1") have not yet been memorised; however,
www.stobag.com
M2
M2
~
~
3
PE
1 2
3
PE
3
PE
1 2
3
PE
2
2LNPE
Brown
Black
Blue
Yellow/Green = Earth
Position 0
MOVENO DWIRE-V
= electrical UP phase
= electrical DOWN phase
= Common
the movement in this case will be interrupted twice, momentarily, at
the start of each manoeuvre, and will then continue unimpeded and
uncontrolled. If only one travel limit has been memorized, the move-
ment will be interrupted only once, momentarily, at the start of each
manoeuvre, and will then continue unimpeded and uncontrolled.
Position 1
GB
MA 2001
15