Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other equipment, do not
use to control receptacles, fluorescent lighting fixtures, or transformer-supplied appli-
ances.
2. When no "ground means" exists within the wallbox, then NEC
exception to (b) allows a control without a ground connection, to be installed as a
replacement. For this type of installation cap or remove the green control ground
wire. A control installed under this exception (NEC
(b)) must be provided with a plastic, noncombustible, UL listed wallplate.
3. Set multi-speed fans to their highest setting before installing controls.
4. Do not use control with a fan and light that operate with the same switch.
5. For new installations, wire a test switch before installing the control.
6. Use controls with a ceiling paddle fan only. Use only one ceiling paddle fan per con-
trol.
7. Do not wire in a circuit with a GFCI breaker/receptacle.
8. Controls may feel warm to the touch during normal operation.
9. Install in accordance with all national and local electrical codes.
10. Clean control with a soft damp cloth only. Do not use any chemical cleaners.
Multi-Unit Installations
When combining controls in one wallbox, remove all inner side sections before wiring
(see below). Use pliers to bend each side section up and down until it breaks off.
Reduction of control capacity is not required.
Remove all inner side
sections (shaded).
Do not remove outer
side sections.
Technical Assistance
?
If you have questions concerning the installation or operation of this product,
call Hampton Bay. Please provide exact model number when calling.
U.S.A. and Canada
Monday to Friday, 8am – 5pm EST
TOLLFREE (866) 353-3685
Limited Warranty
Hampton Bay will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For
warranty service, return unit to place of purchase or mail to Hampton Bay, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS
LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR
REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION.
THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. HAMPTON BAY'S LIABILITY ON ANY CLAIM
FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF
THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow limita-
tions on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limita-
tion of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This product may be covered by Mexican patent 168,884 and one or more of the following U.S. patents: 4,835,343; 4,835,816; 5,191,971;
and corresponding foreign patents. Hampton Bay is a registered trademark of Hampton Bay Fan & Lighting Co. NEC is a registered
trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2004 Hampton Bay Fan & Lighting Co.
At Your Nearest Home Depot.
HAMPTON BAY FAN & LIGHTING CO.
2455 Paces Ferry Road N.W.
Atlanta, GA 30339
Made and printed in U.S.A.
3/04 P/N 033-047 Rev. D
1.5 Amps maximum 120 V~ 60 Hz
Installation
1.5 Amps maximum 120 V~ 60 Hz
For installations involving more than one control in a wallbox, refer to
Multi-Unit Installations before beginning.
1
2002, Article 404-9
®
2
2002, Article 404-9 exception to
®
3
4
Terminal Screws:
Turn screws to loosen.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations
for the supplied wire connectors. Note: Wire connectors provided are suitable for copper
wire only. For aluminum wire, consult an electrician.
033-047
033-047
WARNING: Turn power OFF at circuit breaker
or remove fuse.
Remove switch mounting screws. Pull switch
from wall.
Turn
screws to
loosen.
Verify application.
Switch must have two insulated wires connected to
two screws and a bare copper or green wire con-
nected to a green screw.
Ground
(Bare Copper or Green WIre)
Disconnect switch wires.
OR
Backwired:
Insert screwdriver. Pull wire out.
Small: Strip insulation 3/8" for 14 AWG wire
Strip insulation 1/2" for 16 or 18 AWG wire
Use to join one 14 AWG supply wire with one
16 or 18 AWG control wire.
Large: Strip insulation 1/2" for 10, 12 or 14 AWG wire
Strip insulation 5/8" for 16 or 18 AWG wire
Use to join one or two 12 or 14 AWG supply
wires with one 10, 12, 14, 16, or 18 AWG con-
trol wire.
Large
Small
5
Wiring the control.
Black
Black
Green
Ground
Note: Wire location on control may vary
depending on model.
Control
Hot
Black
Black
120 V~
60 Hz
Green
Fan
Ground
6
Mount and align control. Install wallplate.
Start screws.
7
Turn power ON.
Operation
Medium
High
Low
Twist wire connec-
tor tight.
Be sure no bare
Off
Off
wire is exposed.
Models:
750 426
750 450
• Connect the green wire
on the control to the
bare copper or green
ground wire in the wall-
box (see Important Note
2).
• Connect one of the
black wire on the control
to either of the wires
removed from the
switch.
• Connect the remaining
black wire on the control
to the remaining wire
removed from the
switch.
Neutral
Align control and
tighten screws.
High
Med.
Low
Off
Models:
750 456
750 457

Publicidad

loading

Resumen de contenidos para HAMPTON BAY 750 426

  • Página 1 Limited Warranty Hampton Bay will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For Turn power ON. warranty service, return unit to place of purchase or mail to Hampton Bay, postage pre-paid.
  • Página 2 Operación Hampton Bay reparará o reemplazará a su discreción, cualquier unidad que tenga defectos de materiales o manufactura dentro de un período de un año a partir de cada compra. Para obtener servicios bajo la garantía, devuelva la unidad al lugar de compra o envíe por Cuando se conecten cables, la longitud expuesta de los extremos y la combinación de...

Este manual también es adecuado para:

750 450750 456750 457