OUTPUT
Voltage Range:
Current Range:
Output Voltage Setting:
Output Current Setting:
Operating Mode:
Output Switch:
Output Terminals:
Sensing:
Output Protection:
Load Regulation:
Line Regulation
Ripple & Noise
(20MHz bandwidth):
Transient Response:
Temperature Coefficient:
Status Indication:
METER SPECIFICATIONS
Meter Types:
Meter Resolutions:
Meter Accuracies:
GENERAL
AC Input:
Power Consumption:
Operating Range:
Storage Range:
Environmental:
Safety:
EMC:
Size:
Weight:
0V to 35V minimum
0A to 5A minimum
By coarse and fine controls.
By single logarithmic control.
Constant voltage or constant current with automatic cross-over.
Electronic. Preset voltage and current displayed when off.
Universal 4mm safety binding posts on 19mm (0.75") pitch.
Switchable between local and remote. Spring-loaded push terminals for
remote connection.
Output will withstand up to 40V forward voltage.
Reverse protection by diode clamp for reverse currents up to 3A.
<0.01% of maximum output for a 90% load change, using remote sense.
<0.01% of maximum output for a 10% line change.
Typically <2mVrms, <10mV pk-pk, constant voltage mode.
<200µs to within 50mV of set level for a 5% to 95% load change.
Typically <100ppm/°C
Output on lamp. Constant current mode lamp.
Dual 4 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz.
10mV, 1mA
Voltage 0.3% of reading ± 3digits,
Current 0.5% of reading ± 3digits
220V-240V AC ± 10%, 50/60Hz.
110V-240V AC ± 10% by factory option.
Installation Category II.
400VA max.
+5ºC to +40ºC, 20% to 80% RH.
−40ºC to + 70ºC.
Indoor use at altitudes up to 2000m, Pollution Degree 2.
Complies with EN61010−1.
Complies with EN61326.
140 x 160 x 320mm (WxHxD).
2.8kg
Specification
3