Troubleshooting - RIB ACG6150 Manual Del Usario

Ocultar thumbs Ver también para ACG6150:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TROUBLESHOOTING

The gate would not move, the buzzer is emitting an alternating sound for 1 minute, and one
of the LED EDGE PHOT is blinking red/green.
The gate would not move, the buzzer is emitting an alternating sound for 1 minute, and one
of the LED EDGE PHOT is blinking red/green, OR
the gate is trying to open/close, but stops almost immediately, the buzzer is emitting an
alternating sound for 1 minute, and one of the LED EDGE PHOT is blinking red/green.
All of the LEDs on the MASTER Wi-Fi FR are off
During memorization of the safety devices the buzzer sounds for 3/5 second
During memorization of the safety devices the buzzer sounds 2 twice
When giving a command the buzzer sounds 3 times
When giving a command the buzzer sounds 4 times
The buzzer sounds 5 times when the strip connected to the photocell receiver is pressed
When giving a command the buzzer sounds 5 times
The buzzer emits a sound every 3 seconds for 1 minute and one of the EDGE PHOT leds is
ignited red fixed
The gate doesn't move, the buzzer emits a sound every 3 seconds for 1 minute and one of
the EDGE PHOT leds lights flashing red
LED DL2 is off and one of the dual-color LED EDGE emits a steady green light
Led light DL2 on, Led light DL3 off. Giving a command one of the EDGE LED lights up and
blinks green/red, the gate does not move, and the buzzer emits an alternating tone for one
minute.
Or
the gate starts to open / close and then stops, the buzzer emits an alternating tone for one
minute.
The buzzer does not sound when the batteries are removed from the strip
The door does not open or close and one of the dual-color LEDs emits a steady green light
The door does not open or close, the buzzer emits a sound every 3 seconds for 1 minute and
one of the EDGE PHOT LEDs lights flashing red
The strip connected to the photocell transmitter or receiver does not work as a safety device Check the correct jumper settins of the photocell transmitter/receiver.
PROBLEM
If two MASTER Wi-Fi FR, installed at a distance less than 20 m between them, are commanded
simultaneously, their communication and check signals with the accessories can overlap and
interfere with each other, causing the systems to go into alarm.
Move the two MASTER Wi-Fi FR away from each other over the 20 m.
Failed control between MASTER Wi-Fi FR and the safety device:
- Install the 868MHz aerial (code ACG5451) on the MASTER Wi-Fi FR to guarantee the correct
communication between the MASTER Wi-Fi FR and the safety accessories installed.
Attention: The aerial must be placed in sight of all the safety accessories installed.
If the indication of failure persists, check charge level of the batteries, and if low, replace
them.
Ensure that 12 or 24 V ac/dc power is present to the power feed terminals of the MASTER
Wi-Fi FR
It has been tried to memorize a safety device with wrong DIP setted.
Verify that LED EDGE PHOT which flashes corresponds to the safety device DIP to memorize.
A safety device is already in the memory
- No safety device has been memorized, memorize at least one, OR
- The DIP corresponding to the safety devices memorized are OFF. Turn them to ON
Possible cable missing between the MASTER Wi-Fi FR and the control board:
- Blinker wires to control board detached, OR
- yellow wire (strip) to control board detached, OR
- black wire (photocell) to control board detached
Setup error for the strip contact
- 8,2KΩ resistance not connected in series with the N.C. contact of the strip connected to the
photocell receiver, OR
- Wires detached on the strip with N.O. contact, OR
- 8,2KΩ resistance not connected in series with the N.C. contact of the strip, OR
- Wires detached on the strip with N.O. contact connected to the photocell receiver
Replace the batteries of the photocell(s) or the strip(s) as they are almost empty
Replace the batteries of the photocell(s) or the strip(s) as they are empty
- Wires detached on the strip with N.C. contact, OR
- Ensure that there is resistance of 8,2kΩ in series with the N.O. contact of the strip connected
to the photocell receiver
MASTER programmed only with safety edges TOUCH Wi-Fi.
Remove the MASTER black wire from the photocell contact on the control panel, and if there
are no hard-wired photocells installed, put a jump-link between the photocell and common
inputs on the control panel.
Ensure that the DIP on the MASTER Wi-Fi FR corresponding to the strip is in the ON position
- Photocell is not aligned or it is engaged. Batteries in the photocell transmitter are exhausted,
OR
- 8,2kΩ resistance is not connected in series with the N.C. contact or in parallel with the N.O.
contact of the strip connected to the photocell transmitter, OR
- 8,2kΩ resistance is not connected in parallel with the N.O. contact of the strip connected
to the photocell transmitter
Photocell receiver or strip batteries are empty
If jumpers are correctly setted, remove and put again the batteries.
25
CHECK
G
B

Publicidad

Tabla de contenido
loading

Tabla de contenido