The display resolution of "FL OZ" & "CUPS" is 1/8. If fi ner resolution and higher accuracy is required, please select mL (or
gram) for the measurement and convert back to FL OZ or CUPS if needed.
Tare (set zero) Function
It is easy and convenient to build up & mix diff erent ingredients together all in the same cup. After the fi rst ingredient
is added and measured, you may add another ingredient after performing the tare function below.
• Place the cup with fi rst ingredient on a fl at table.
• Single press [0] button. The reading will reset to zero and the "TARE" icon will remain on the upper display.
Now you can add your additional ingredient. Only the weight or volume of the last ingredient added in measured.
Continue above procedure to build up diff erent ingredients for your recipe.
NOTE: The tare function only operate when the cup is placed on a fl at surface
Reversing the Tare Function
Right after the tare function has been performed and the display is showing "0" reading with the "TARE" icon appeared,
you can press [0] button to resume the original weight or volume reading just before the tare function and the "TARE"
icon will disappear.
NOTE: The reverse tare function only operate when the cup is placed on a fl at surface
IMPORTANT NOTE: It is easy and convenient to mix diff erent ingredients in the cup. However when mixing your
ingredients, you should avoid pressing down the bottom of the base where the sensitive weight scale components
are located. Excessive force applied to the base of the cup may permanently damage the scale inside and provide
inaccurate reading.

FAULT MESSAGE DISPLAY

UnSt: Unstable
The scale is unstable and the unit will turn off automatically. Place the cup on a fl at table and turn on the unit again by
pressing [0] button once.
Err: Error
The scale is overloaded. The weight or volume in the cup exceeds the maximum display range
(refer "Specifi cation" section).

CALIBRATION

To ensure accurate measurement, you are suggested to check the weight of an empty cup every time you fi rst turn on
the unit. It should read 0 gram (or oz) for your empty cup.
Calibration for the cup is needed ONLY when the reading of your EMPTY cup is higher than zero (gram, oz, cups, fl oz or
ml). The calibration process will reset the reading to zero for the empty cup.
To calibrate:
1. Make sure the transparent cup is attached to the base.
2. Make sure the cup is empty. Clean the unit with a dry cloth to remove any excess liquid on the cup.
9