3
M18™ 500GB CONTROL HUB
Remove the four combination head screws to access the camera test port
1. With the CONTROL HUB powered off, remove it from the reel.
2. On the rear of the CONTROL HUB, remove the four combination head screws from
the camera test port cover.
3. Screw the camera head onto the male threads of the test port. Hand tighten only.
4. Power on the CONTROL HUB.
5. Power on the M18™ WIRELESS MONITOR or tablet running the Milwaukee® Pipeline
Inspection App, and connect to the CONTROL HUB checking for picture and control of
the cameras LED's.
3.4 Formatting the M18™ CONTROL HUB INTERNAL
and THUMB DRIVEs
This setting allows the formatting of the M18™ 500GB CONTROL HUB's Internal 500GB
Drive or Thumb Drive.
The system requires that Thumb Drives be formatted in the FAT32 file system.
1. Turn the navigation dial to SETTINGS
2. Turn the navigation dial to FORMAT DISK, press the navigation dial to enter the sub-
menu.
Select the CONTROL HUB Internal Drive (HUB SSD) or the CONTROL HUB Thumb
Drive (HUB USB) and press the navigation dial.
CONTROL HUB INTERNAL DRIVE
CONTROL HUB THUMB DRIVE
, press the navigation dial.
SETTINGS