OPERATING INCIDENTS
The suction cup does not adhere to the
component.
Deficient aspiration, Vacuum.
1 Verify if the suction cup is well placed and in
perfect condition.
2 Verify the filters at the entrance of the pump,
and change them if dirty or obturated, therefor:
Disconnect the filter plug tube. Unscrew the
plug and remove the gasket.
Remove the three paper filters, throw away the
dirty ones and replace with new ones.
Insert the three filters and the gasket in this order;
screw-up the cover and connect the tube.
Check for air tightness.
Error messages
Whenever the ERR message appears, the
equipment turns itself off completely.
The following messages are displayed:
- BLANK SCREEN
Power failure.
Check for blown fuses.
- ERR 1
The temperature will not rise.
Possible causes: heating element open or blown
fuse.
- ERR 2
The temperature is rising out of control.
Possible causes: shorted triac or insufficient
airflow.
- ERR 3
No reading from the thermocouple.
Possible cause: open thermocouple.
- ERR 4
Erratic readings from the thermocouple.
Possible causes: the thermopar or its
connections are in poor condition.
5