5.4 Multiplying factor (counter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
5.5 Dividing factor (counter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
5.6 Decimal point (counter)
The decimal point defines the
way of displaying the count val-
ues. It does not affect counting.
0
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
5.7 RESET Mode (counter)
manual reset via the red
RESET key
no reset (red RESET key
locked)
5.8 Multiplying factor (frequency meter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
5.9 Dividing factor (frequency meter)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
3
no decimal place
5.10 Decimal point (frequency meter)
The decimal point defines the
resolution in the selected
measuring range 1/min or
1/sec
0
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
5.11 Display mode (frequency meter)
Value conversion and
display in 1/s
Value conversion and
display in 1/min
5.12 Max. time to wait until „0" is displayed
(frequency meter)
This parameter indicates, how long it takes, when
measuring is active, until „0" is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
5.13 End of programming
The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
no decimal place