6. Technical data
Supply voltage
DC power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
DC power supply:
Input level:
Standard 5V
typ. level low:
typ. level high:
22,0 V
Fmax:*
ContDir/Tacho
UpDown/Tacho
Up.Up/Tacho
Quad 1/Tacho
Quad 2/Tacho
Quad 4/Tacho
Frequency measurement (INP C):
Accuracy :
Measuring principle:
< 38 Hz:
> 38 Hz:
Input sensitivity:
Standard sensitivity:
DC power supply
4 ... 30 V DC level: Low: 0 ... 2 V DC
Pulse shape:
Ambient temperature:
-20 ... +65 °C at
10 ... 26 V DC
-20 ... +55 °C at >26 ... 30 V DC
10 ... 30 V DC/max. 55 mA
with inverse-polarity protec-
tion
6 digits, red 7 segment
LED display, height 8 mm
EEPROM
Programmable, npn or pnp
for all inputs
appr. 5 k
24 V
12 V
10 ... 30 V
2,5 V
2,0 V
1,0 V
10 V
4,0 V
kHz
kHz
kHz
30
10
8
10
10
8
10
10
8
15
10
8
15
10
8
10
8
8
< 0.1 %
period measurement
gating time measurement
gating time = 26,3 ms
Low: 0 ... 0,2 x U
[V DC]
B
High: 0,6 x U
... 30 [V DC]
B
High: 4 ...30 V DC
any*,
Schmitt-Trigger inputs
Storage temperature:
Altitude:
EMC:
Noise emission
Noise immunity
Housing:
For front panel mounting: 48 x 24 mm
acc. to DIN 43700, RAL7021, dark grey
Weight:
Protection:
* at maximum frequency square wave pulses 1:1
Cleaning:
The front of the units is to be cleaned only with
a soft wet (water !) cloth.
7. Terminal assignment
1 10 ... 30 V DC
2 0 V GND
3 INP A
4 INP B
5 INP C
8. Delivery includes:
1 Digital display
1 Panel mounting clip
1 Bezel for screw mounting, panel cut out
50 x 25 mm
1 Bezel for clip mounting, panel cut out
50 x 25 mm
1 Seal
1 Multilingual operating instructions
9. Ordering code:
6.52P.012.3X0
–25 ... +70 °C
to 2000 m
EN 55 011 Class B
EN 61 000-6-2
appr. 50 g
IP 65 (front)
Input sensitivity
0 = Standard
A = 4 ... 30 V DC level
4