SPE C IF I CAT I ON S
Discharge
Outdoor Wall Hoods have a vertical discharge. Refer to the
illustration below.
2"
(51)
Vertical discharge
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations and
chart below. A separate circuit, servicing only this appliance
is required.
A ground fault circuit interrupter (GFCI) is required to reduce
the risk of electrical shock.
E L E C T R I C AL R E Q U I R E M E N T S
Electrical Supply
Service
E L E C T R I C AL K N O C KO U T L O C AT I O N
36"
Hood
(914)
48"
Hood
(1219)
60"
Hood
(1524)
36"
42"
(914) TO
(1067) BOTTOM EDGE TO COUNTERTOP
Hood location
5
2
/
"
8
(67)
A
17"
(432)
Electrical knockout location
grounded, 120 VAC, 60 Hz
15 amp dedicated circuit
16"
(406)
22"
(559)
28"
(711)
RATING PLATE
Rating plate location
wolfappliance.com | 5