12. ALARMS
Error reset can be automatic or manual, depending on the error that occurs. Manual reset is carried out using the
enter button and then start to restart the pump.
Code
Description
EN
Er01
Blockage due to no water
Faulty pressure sensor – Max. ressure
Er02
exceeded
Er03
Blockage due to low supply voltage
Er04
Blockage due to high rectified voltage
Er05
Blockage due to exceeded of number of starts
Blockage due to overcurrent in the electro
Er06
pump motor
Er07
Pump not fully primed
Er08
Blockage due to internal overheating
Er09
Blockage due to overpressure
Er10
Thermal-protector intervention detected
Er11
Blockage due to presence of air
From Er27
Internal hardware error
to Er32
In case of internal hardware error contact an authorised service center.
13. WARNING
The Warning remains active until the input cause is no longer effective. In Warning status the pump could still
operate normally but advising that it is working nearby the limits of an Error status.
Code
Symbol
W1
W2
W3
W4
W5
Page 18 / 80
Causes
20 restarts with stand-by time less than
5s
The pump is not properly primed or
there is air inside the pump casing. The
pump restarts whenever the system
pressure is under the restart pressure
threshold.
20 restarts with pump RUN time less
than 10s
The power is under the switch-off
attempt threshold for 60s with set-point
pressure reached
The pump is at the limit of the allowed
power input and the pressure is less
than 1.5bar for 20s
Reset
Causes
ERR
The device is in failure due to no water.
MAN
The system try to restart automatically and
make one attempt every 10 minutes for 5 times.
MAN
Faulty pressure sensor
Supply voltage lower than 185V.
AUT
- The system automatically restart when the
clamp voltage is higher than 190V.
Supply voltage higher than 225V.
AUT
- The system automatically restart when the
clamp voltage is lower than 250V.
The system has started more than 90 times in
MAN
1 hour
The system try to restart automatically and
MAN
make one attempt every 10 seconds for 3
times.
The system try to restart automatically and
MAN
make one attempt every 10 minutes for 5 times
AUT
Overtemperature detected on the board.
MAN
Pressure greater than 7.8 bar.
MAN
Motor overheating
MAN
Presence of air inside the pump casing.
MAN
Possible remedies
Check the membrane pressure, if necessary
install a tank of at least 8 liters
Make sure that the pump casing is full of liquid
and that all the air has been expelled.
Check if there are small leaks in the system
META Rev1-1 - Operating Instructions