Installation
1
Marking the installation hole
□
Select a location near an outside 120-volt covered GFCI outlet cover plate
marked for WET LOCATION. Using the mounting template (DD), mark holes
for the power pack (G) at least 20 in. above ground level.
2
Installing the anchor
□
Mark the bottom holes on the power pack (G) for installation.
□
Drill holes using a 1/4 in. drill bit (not included). Install plastic anchors (CC)
and Phillips screws (AA), leaving enough space for the power pack (G).
3
Stripping the low-voltage cable
□
For low-voltage cable connections, split one end of the low-voltage cable (H)
approximately 2 in., and then strip about 3/4 in. of insulation of each wire
before twisting strands together tightly.
4
Connecting the low voltage cable to the
power pack
□
Loosen the terminal screws located on the bottom of the power pack (G)
and insert one of the pre-stripped wires (H) under the terminal clamping plate
"COM" and securely tighten the terminal screw. Repeat this process for the other
side of the wire (H), inserting it into the second wire terminal clamping plate "12V".
CAUTION:
pack (G), ensure there is no wire insulation under the terminal clamping plate
and the screws connecting the cable to the power pack terminals are securely
tightened.
5
Installing the photocell cable or the
cover to the power pack
□
cable (FF) into the
photo eye socket on the bottom of the power pack (G).
Make sure the photocell cable (FF) is never crimped in any way.
□
If you dont want to use the photocell cable, then place the cover (GG)
photo eye socket on the bottom of the power pack (G) to protect the power
pack from dust and moisture.
insert the end of the photocell
into the
5
DD
G
H
Please contact 1-855-235-8715 for further assistance.
20 in. (50.8 cm)
CC
AA
2 in. (50,8 mm)
3/4 in.(19 mm)
H
G
COM 12V
G
FF
G
GG
HOMEDEPOT.COM