Postseason storage
When the air conditioner is out of season or not used for long time, corresponding maintenance measures
should be taken.
• Drain all water in water pan from outlet (water can be poured out by slowly leaning the body backward
during drainage), and adjust operating mode to FAN mode, and then press SPEED for 5s till fan works, keep
this operating mode for 2~3h. This method can dry inside of the body and prevent mildew.
• Turn off the air conditioner and pull out power plug.
• Wind up, fasten and put away power line.
• Remove exhaust pipe and keep properly.
• Set the air conditioner into plastic bag and put it in a dry place.
• Take out of cells of remote control and keep properly.
Fault
Possible Cause
Power off?
Plug not inserted?
The air
Fuse burnt out or power supply turned off?
conditioner
does not work.
Time set properly?
Water full alarm?
Air inlet/outlet blocked?
Other heating sources available in room?
COOL effect
Strainers too dirty?
not good.
Temperature setting appropriate?
Fan speed set at LOW?
Noise too large
Body inclined? Ground uneven?
and shake.
Caution: when the following abnormalities occur to the air conditioner, shut down and pull out the plug, and
then contact a professional electrician.
• Fuse and switch are often broken.
• Power line is overheating or its coat is naked.
• The body produces abnormal odour.
Error Codes
E1: Abnormal sense of coil pipe sensor
E2: Abnormal sense of room temperature sensor
E4: Anti-frost protection
FL: The air conditioner is in water full alarm state
Troubleshooting
NOTE: When heating indicator is displayed, the air
conditioner is in anti-freezing or defrosting state,
and this is a normal phenomenon.
Solution
Normal phenomenon.
Insert power plug steadily.
Replace fuse or turn on power supply.
Change time setting.
Pour water.
Remove blocking.
Remove other heat sources.
Clean strainers.
Change temperature.
Select appropriate speed.
Put the air conditioner on even ground.
24