EnviraCOM™ Alarm Module
APPLICATION
The EnviraCOM™ enabled W8735S3000 Alarm Module, when
connected to the R7284 Oil Primary, L7224/L7248/L7103
Aquastat ®, and/or other EnviraCOM enabled, alarm
generating controls will close dry contacts to indicate a
critical alarm event.
FEATURES
• Works with any alarm generating EnviraCOM enabled
control
• Local LED alarm present indication
• Local LED communication active indication
• Screw terminals
• Simple low-voltage, 5-wire installation (3 EnviraCOM, 2
relay dry contacts)
• EnviraCOM™ Enabled
SPECIFICATIONS
Electrical Ratings: Voltage: 24 Vac, 60 Hz supplied through
the EnviraCOM bus.
Contact Rating: 1A at 24 VAC
Environmental Ratings:
Temperature: -30° F to +150° F (-34° C to +66° C).
Humidity: 0 to 95% relative humidity, non-condensing.
Relay Specs:
Normally open (N.O.), dry alarm contacts close upon the
receipt of a critical EnviraCOM alarm
INSTALLATION INSTRUCTIONS
Compatibility
The W8735S3000 Alarm Module is compatible with the
following EnviraCOM enabled controls:
• R7284/R7184 Oil Primary
• L7224/L7248/L7103 Aquastat®
• S9200U Universal IFC
• WV4460 Power Vent Water Heater Control
• S9360/S9361 Integrated water heater and boiler controls
• W8735G EnviraCOM Gateway
• W8735D EnviraCOM Telephone Access Module
• R7910 SOLA Control
• W8735S1000 Outdoor Reset Module
• W8735S1008 Domestic Hot Water Module
• W8735S1016 Indoor Temperature Module
• W8735S2000 Flood Module Kit
• W8735S2008 Sump Pump Module Kit
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.
3. The installer must be a trained, experienced service
technician.
4. After installation is complete, check out product opera-
tion as provided in these instructions.
CAUTION
Can cause electrical shock and equipment damage.
Disconnect power supply before connecting wiring.
5. The EnviraCOM Alarm Module can be wall mounted in
any orientation desired or dictated by the surroundings.
6. The holes are sized for the #6 sheet metal screws
(included).
7. Precise leveling of the product is not required.
69-2522EFS-03