Compact Compressor
Nebulizer
Model# : 240392
Please read lines instruction manual completely
before operating this unit.
Caution - Federal (U.S.A.) restricsts this device to safe,
by or on the order of a physician
,
Components
01. Compressor housing
02. Lid
03. Air vents
04. ON/OFF switch
05. Power cord
06. Air outlet
07. Filter holder
Standard accessories
08. Nebulizer
09. Mouthpiece with T-connector
10. Tubing
11. Adult mask
12. Pediatric mask
13. Air filter (5pcs)
Instructions for use
Nebulizer
This device is an AC-powered air nebulizer compressor
system intended to provide a source of compressed air
for medical purposes for use in home healthcare
environment. It is to be used with the nebulizer kit to
produce aerosol particles of medication for respiratory
therapy for both children and adults.
Important:
Read these instructions carefully before using this
device.
General information
The compressor nebulizer system is for aerosol therapy
and it is supplied with the nebulizer kit.
Caution
1. Use the device only for its intended purpose as
described in these instructions for use as a
compressor nebulizer system for aerosol therapy.
Follow the instructions of your doctor. Any other form
of use constitutes improper use and may be dangerous.
The manufacturer cannot be held liable for any damage
caused by improper, incorrect or unreasonable use, or if
the unit is connected to electrical installations not
complying with safe regulations.
2. Keep this manual for future reference.
3. Do not operate the unit in the presence of any
anesthetic, inflammable mixtures or oxygen.
4. Device operation can be affected by electromagnetic
interference that exceeds the limits indicated by the
USFDA standards in force. If this device interferes with
another electrical apparatus, remove it and plug it into a
different electrical outlet.
5. In case of failure and / or malfunction, do not open the
compressor housing as this is not a serviceable product.
6. The proper function of the device can be
compromised if original replacement parts (e.g. filter) are
not used.
7. When using any electrical appliance, certain important
safety measures must always be observed, including the
following:
• Use only original accessories and components
• Never submerge the unit in water as the device is not
protected against water penetration
• Never touch the unit when your hands are wet or moist
• Do not leave the unit outdoors
• Place on stable and horizontal surface while operating
• Make sure the air vent openings are not obstructed
• Do not allow children or physically challenged
individuals to use the unit without supervision
• Do not turn the unit OFF by simply pulling out the plug
form electrical outlet
8. Make sure that the electrical rating shown on the
rating plate at the bottom of the unit corresponds to your
main voltage and frequency before plugging in the
device.
9. Do not use any adapter (simple or multiple), and / or
extension cable.
10. Unplug the device from the electrical outlet when not
in use.
11. The power supply cord should always be fully
unwound in order to prevent overheating.
12. Before performing any cleaning operation or filter
replacement, disconnect the device from the main
supply by unplugging it or by turning the main supply
OFF.
13. Some parts of the unit are small enough to be
swallowed by children. Do not let children or physically
challenged individuals have access to the unit without
supervision.
14. If you decide not to use the device, it is
recommended to dispose of the device according to the
local regulations in force.
15. Remember to:
• Use this device only with medication prescribed by your
doctor

Publicidad

loading

Resumen de contenidos para Procare 240392

  • Página 1 The compressor nebulizer system is for aerosol therapy 11. The power supply cord should always be fully Model# : 240392 and it is supplied with the nebulizer kit. unwound in order to prevent overheating. 12. Before performing any cleaning operation or filter...
  • Página 2 • Use the accessories recommended by your doctor for the “Cleaning and disinfection of the accessories” The device does not nebulize, or the nebulization is therapy section. weak: 16. Verify that the medication prescribed by your doctor 1. Make sure the ends of the air tube are fitted tightly can be used with common compressor nebulizer onto the main unit and onto the nebulizer.
  • Página 3 • No apague la unidad simplemente retirando el enchufe Información General del tomacorriente eléctrico Model# : 240392 El sistema nebulizador compresor es para terapia de 8. Asegúrese de que la clasificación eléctrica que se aerosol. Y se suministra con el kit nebulizador.
  • Página 4 13. Algunas partes de la unidad son lo suficientemente muestra en la placa de características en la parte inferior Reemplazo del Nebulizador El nebulizador debe reemplazarse después de un largo pequeñas para ser tragadas por niños. No permita que de la unidad corresponda a su voltaje principal. 12.