Default button settings
DIP S2
DIP 1 DIP 2 DIP 3 DIP 4
P1
0
0
0
0
CCS
1
0
0
0
ACT
0
1
0
0
INT
1
1
0
0
ACT
0
0
1
0
ACT
1
0
1
0
INT
0
1
1
0
1
1
1
0
INTb
0
0
0
1
CCS
1
0
0
1
0
1
0
1
CCP
1
1
0
1
PAN
0
0
1
1
1
0
1
1
INT
0
1
1
1
NULL
1
1
1
1
A
Lock- release
Speech
ACT
Actuator
AI
Self-ignition
CCP
Main switchboard call
General button programming warnings
If the default settings (see table on page 27) do not refl ect requirements,
the buttons can be programmed differently by carrying out the steps below.
At the end, set S2 DIP switches 1-2-3-4 to the combination 1111
(PROG setting in the confi guration tables on pages 27, 28, 29). In this
dip switch setting, the buttons control the programmed functions;
Programming buttons for generic or coded actuator
DIP S2
DIP 1
DIP 2
DIP 3
DIP 4
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
0
1
1
0
0
1
0
1
0
1
1
1
0
1
0
0
1
1
1
0
1
1
0
1
1
1
1
1
1
1
Example:
on a monitor with user code 5, P1 programming = generic actuator, P2 =
coded actuator (code 125)
1. Set S2 DIP switch 5-6 to the combination 01
» LED 1 (red) fl ashes
2. Refer to the table on page 27 and select a combination in which the
actuator function (ACT) is listed for the buttons you wish to program.
E.g.: for P1= generic actuator, set S2 DIP switches 1-2-3-4 to the
A
P2
AI
AI
A
AI
CCS
ACT
ACT
ACT
AI
D
INT
PAN
A
K
CCS
K
CCP
D
INTb
INT
NULL
NULL
NULL
CCS
K
D
PAN
INT
A
P1
P2
ACT
A
ACT
ACT
ACT
ACT
ACT
A
2
LED1
P3
P4
ACT
D
INT
INTb
INTb
ACT
CCP
PAN
ACT
ACT
CCS
CCP
K
CCS
AI
INT
D
AI
PAN
CCP
PAN
ACT
CCS
K
INT
ACT
INT
INT
NULL
NULL
PROG
Legend
Switchboard call
Guardian door-entry
phone call
Doctor
Panic
Programmable
intercom, general or
selective
- general internal call
as standard for KIT and
Simplebus Top
the NON-programmed buttons control functions referred to on line
0000 (see table on page 27). Restore the user code setting on S1, see
table A on page 26.
with Art. 6333
P3
P4
P5
ACT
ACT
ACT
ACT
ACT
ACT
ACT
ACT
PROG
combination 1000 or 1100 or 0010 (P1=ACT), set S1 DIP switches to the
combination 11111111, go to point 3
E.g.: for P2= coded actuator (code 125), set S2 DIP switches 1-2-3-4
to the combination 0010 or 1010 (P2=ACT), set S1 with address 125 in
accordance with table A on page 26, go to point 3
3. Press and release the button to be associated with the function
LED 2
»LED 2 (blue) fl ashes 4 times
»confi rmation tone
4. To exit programming mode, set S2 DIP switches 5-6 to the combination
00
» LED 1 (red) switches off
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the
combination 1111. Restore the user code setting on S1, see table A
on page 26.
with Art. 6333
P5
P6
PAN
K
D
CCS
CCS
CCP
K
D
ACT
ACT
INTb
PAN
CCP
INTb
PAN
D
INT
INTb
AI
INT
INT
AI
ACT
D
AI
CCS
INT
INT
NULL
NULL
Two-family intercom
INTb
- for KIT only
NULL
No function
Programmed functions,
see pages 27-32
In this Dip switch setting,
the buttons control the
PROG
programmed functions; the
NON-programmed buttons
control functions referred to
on line 0000
P6
P7
ACT
ACT
ACT
P7
CCP
PAN
D
AI
ACT
K
INT
ACT
CCP
INTb
CCS
AI
CCP
INT
NULL
DIP S1
ADDRESS
27
27