Programming for intercom call

Use the selective internal call ONLY in conjunction with the internal unit Art. 6302 or with door-entry phones Art. 2610 with R.I. 20 or greater, Art.
2619 with R.I. 20 or greater.

Programming/deleting intercom address (selective intercom only)

Take note of the S2, S1 setting and restore it when programming is complete
1)
S1
Programming; set code, TAB. B on page 28
You must set the intercom address on all the riser's internal
units.
You can assign the same intercom address to a maximum of
3 internal units.
For group calls, select the desired intercom codes
simultaneously (max. 3).
Cancellation
DIP ON
TAB. B Selective intercom addresses
Codice / Code
Dip switch ON
1
1
2
2
3
3

Programming buttons for intercom call

DIP S2
DIP 1
DIP 2
DIP 3
DIP 4
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
0
1
1
0
0
1
0
1
0
1
1
1
0
1
0
0
1
1
1
0
1
1
0
1
1
1
1
1
1
1
Example 1 - Selective intercom
on a monitor with user code 1 and intercom address 1, P3 programming =
selective intercom with address 2, P4 = selective intercom with address 3
Example 2 - KIT intercom (intercom between 2 contiguous addresses in
the range from 1 to 30, with the fi rst being an odd number):
on a monitor with user code 1, P3 programming = general internal call, P4
= two-family intercom with address 2
1. Set S2 DIP switch 5-6 to the combination 01
»LED 1 (red) fl ashes
2. Refer to the table on page 28 and select a combination in which the
intercom function (INT or INTb) is listed for the buttons you wish to
program.
E.g. 1: for P3= selective intercom, set S2 DIP switches 1-2-3-4 to the
28
28
DIP
DIP
DIP
1
2
0
0
1
1
S1
Codice / Code
Dip switch ON
4
5
6
A
P1
P2
INT
INT
A
INTb
INT
INTb
INT
INT
2
LED1
LED 2
2)
DIP
DIP
DIP
S2
3
4
5
6
0
1
1
1
1
1
1
1
S1
4
5
6
with Art. 6333
P3
P4
P5
INT
INTb
INTb
INTb
INT
INT
INT
INT
INT
INT
INT
PROG
combination 1000 or 0011 or 1011 (P3=INT), set S1 with address 2 in
accordance with table B on page 28 and move on to step 3
E.g. 1: for P4= selective intercom, set S2 DIP switches 1-2-3-4 to the
combination 1110 or 1011 (P4=INT), set S1 with address 3 in accordance
with table B on page 28 and move on to step 3
E.g. 2: for P3= general internal call and P4= two-family intercom, set S2
DIP switches 1-2-3-4 to the combination 1000 (P3=INT, P4=INTb), set S1
with user code 1 in accordance with table A on page 26 and move on to
step 3
3. Press and release the button to be associated with the function
»LED 2 (blue) fl ashes 4 times
»confi rmation tone
4. To exit programming mode, set S2 DIP switches 5-6 to the combination
00
» LED 1 (red) switches off
5. When programming is complete, set S2 DIP switches 1-2-3-4 to the
combination 1111. Restore the user code setting on S1 (see table A
on page 26).
3)
1
A
Codice / Code
Dip switch ON
7
7
8
8
P6
P7
ADDRESS
INTb
INT
INTb
INT
INTb
INT
INT
2
OK Prog.
1
KO Prog.
S1
DIP S1