Pentair MYERS MSE50 Manual De Instalación Y Servicio página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Disconnect four wires that
connect the switch to the
motor housing.
6. Remove and discard the
gasket between the switch
and the pump. Clean the
gasket surface on the
motor housing.
7. Remove old switch and
replace.
8. Make sure the fork on the
rod fits over the switch
lever.
9. Set the new gasket on
the motor housing, then
connect the four wires on
the new switch to the four
terminals in the motor
housing
(see Figure)
NOTICE: When you connect
the two power wires to the
cord terminals, make sure
that the wire ends don't
lodge between the cord pin
and the side of the cord
plug. The connector must
be on the pin.
10. With the switch guard in
place, set the switch on
the motor housing with
the switch arm pointed
toward the discharge side
of the pump and install and
tighten the four screws
which secure the switch to
the pump.
11. Holding the float out
sideways, hook the float
rod on to the switch arm
and swing the float rod
down.
12. Insert the float rod in the
hole in the tether strap.
13. Reinstall the pump in the
sump, check all piping
connections, and reconnect
the power. Run the pump
through one complete
operating cycle to check for
proper operation. Failure
to make this operational
check may lead to flooding
and will void the warranty.
7222 0717
7222 0717
5 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mse5012p10Mse5012p20Mse5022p10Mse5022p20

Tabla de contenido