Charger/Controller Unit Installation
Charger/Controller Electrical Ratings:
Input: 120 VAC, 0.2 Amp
Output (Maximum Charging Current):
• Model 1HF: 12 VDC, 900 Milliamps
Use only with 12 VDC deep cycle battery rated 85 – 140Ah, lead-acid or AGM
s
WARNING
!
Do not use in explosive atmospheres. Do not handle charger/controller unit with wet hands or when standing on a wet or
damp surface, or in water.
s
WARNING
!
To reduce risk of electric shock that can result in personal injury, death or major property damage if ignored, be certain that the
115 VAC pump and the charger/controller unit are connected to outlets protected by ground fault circuit interrupters (GFCI). Comply with all national and local
electrical and plumbing codes when installing this unit. Do not use the same 115 VAC outlet for the primary pump and the battery charger/controller unit.
Do not use an extension cord.
s
WARNING
!
A spark near the battery may cause an explosion. Always unplug the charger/controller unit prior to making connections to or
disconnections from the battery. Take care to prevent accidental shorting across battery terminals during handling. Do not leave battery uncovered. Attach or
strap cover securely on battery box when completing installation.
s
CAUTION
!
The battery required to operate this unit contains acid and proper precautions must be taken when handling. Refer to battery
manufacturer's safety guidelines. Failure to use proper personal protective equipment or electrical caution can result in hazards that will or can cause
personal injury or major property damage if ignored.
s
CAUTION
!
If a carbon monoxide (CO) sensor is installed near the battery backup system, battery, or charger/controller unit, nuisance or false
alarms could result. CO detectors should be a minimum of 15 feet from the systems. Refer to the manufacturer of CO detector for additional instructions or
information.
s
CAUTION
!
The backup pump relies on a sufficiently charged battery to operate the pump. The charger is designed to charge the battery and
maintain charge level when the backup pump is not in use. If battery voltage drops below 10 Volts, the backup pump must be disconnected from the circuit
for the charger to recharge the battery.
s
NOTICE
!
The charger/controller unit emits an audible alarm when running the 12 VDC backup pump. An additional (not supplied in this kit)
audible high water alarm on the sump system is recommended in any installations where property damage and/or personal injury might result from an
inoperative sump system due to long term power outages, discharge line blockage, or any other reason.
8
MICRO PROCESSOR
CONTROLLED
5 STAGE
BATTERY CHARGER/
MAINTAINER
WHEN YELLOW - GREEN FLASHING ALTERNATELY
REFER TO ERROR TABLE IN MANUAL
Charger Unit
BATTERY CONNECTION
CHARGER CONNECTION
FLOAT SWITCH CONNECTION
REPLACE FUSE WITH SAME 20 AMP 38V TYPE
AND RATING ONLY
PUMP FUSE &
CONNECTION
DISABLE ENABLE
AUDIBLE ALARM
DISABLE WHEN LIT
Junction Box