Idiomas disponibles

DIP SW 4 (PB NUMBER – ALARM DELAY TIME)
ACTIONS
Power Box
1
OFF
1
ON
2
OFF
3
ON
4
OFF
5
ON
6
OFF
7
ON
8
The dip-switches 1 – 2 – 3 select the alarm/preset type managed by Power Box.
Type 1 and 2 for Urmet EASY Dome only.
Type 1 : alarm detection from nr. 1 to nr. 8.
Type 2: alarm detection from nr. 9 to nr. 16.
Type from 3 to 8: for any Speed Dome kind (refer to manual alarms programming procedure).
Type 3: preset sending from 1 to 8.
The dip-switches 4 and 5 select the minimum time between two consecutive alarm actions.
Note
The Dip-switch setting operations must be performed when the devices are unpowered.
INSTALLATION
After the place where to install the camera is found, follow the instructions below:
Make the fixing holes according to the wall type (cement or wood) and prepare the fixing
devices (screw anchors, screws, etc.)
Fix the connection Power Box to the surface.
Open the Power Box by unscrewing the four screws on the cover corners.
Insert in the wire grommets all the cables needed for the correct operation of the camera. For
outdoor installations, pay attention to close hermetically the wire grommets, in order to maintain
the IP protection grade.
Position the Ref. 1093/709 alarm card inside the Power Box, fixing it with the screws provided
as indicated in the image below.
DS1092-228
Dip-switch
2
3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
ALARM DELAY TIME
Delay in Sec.
Dip-switch
4
OFF
3 S
ON
6 S
OFF
9 S
5
OFF
OFF
ON
13