WARNING
!
To avoid unpredictable system behavior that can cause personal injury and
property damage:
Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
Disconnect air supply and depressurize all air lines connected to this
product before installation, servicing, or conversion.
Operate within the manufacturer's specified pressure, temperature, and
other conditions listed in these instructions.
Medium must be moisture-free if ambient temperature is below freezing.
Service according to procedures listed in these instructions.
Installation, service, and conversion of these products must be performed
by knowledgeable personnel who understand how pneumatic products
are to be applied.
After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for proper
function and leakage. If audible leakage is present, or the product does
not operate properly, do not put into use.
Warnings and specifications on the product should not be covered by
paint, etc. If masking is not possible, contact your local representative
for replacement labels.
WARNING
!
Product rupture can cause serious injury.
Do not connect regulator to bottled gas.
Do not exceed maximum primary pressure rating.
Safety Guide
For more complete information on recommended application guidelines, see the
Safety Guide section of Pneumatic Division catalogs or you can download the
Pneumatic Division Safety Guide at: www.wilkersoncorp.com
INSTALLATION
1.Refer to the above WARNING before installing regulator.
2.Make sure that system piping and regulator are the same pipe size. Avoid
using fittings, couplings, etc. that restrict airflow.
3.Install unit as near as possible to regulated air application.
4.Position unit so air flows in direction indicated by arrow on the top or
bottom of regulator body.
5.Regulator may be installed with adjusting knob located in the up or down
position only.
6.Panel mount regulators require a 1-1/4" (31,7 mm) diameter hole and are
mountable on panels up to 1/8" (3,2 mm) thick. To panel mount regulator
or install using L-Type (wall mount) bracket, snap off adjusting knob by
rotating the panel nut counterclockwise allowing the mechanical
advantage of the screw thread to lift the knob off. Fit bonnet threads into
panel or bracket hole. Replace panel nut and tighten. Replace adjusting
knob by snapping back onto regulator bonnet.
OPERATION
1.NOTE: Maximum pressure rating is 300 psig (21 bar). Temperature
range is 32°F to 150°F (0°C to 65,6°C).
2.To adjust regulator pull up on adjusting knob.
3.Before turning on supply air pressure, turn the adjusting knob
counterclockwise until there is no load on the regulating main spring.
4.To set the downstream pressure turn on the supply air pressure and then
turn the adjusting knob clockwise until the desired secondary pressure is
reached. Push the adjusting knob down to lock knob in place.
5.When making a change in pressure setting, always approach the desired
pressure from a lower pressure. When reducing from a higher to a lower
setting first reduce to some pressure point less than that desired and
then increase to the desired pressure.
MAINTENANCE
1.Given normal operating conditions this unit will be trouble-free. For long
service life, occasionally disassemble and clean body, diaphragm,valve
and valve seat. Service unit at least every six months.
2.TO REPLACE OR SERVICE VALVE ASSEMBLY:
a. Depressurize unit.
b. Turn adjusting knob counterclockwise to relieve compression on spring.
c. Insert flat head screw driver into bottom plug slot and slowly rotate
counterclockwise.
d. Remove bottom plug and bottom valve spring. Valve assembly can
now be removed for cleaning or replacement. When replacing valve
Tel: (269) 629-5000
Installation & Service Instructions
84-018-000
Regulator Model R08
With Variations and Accessories
ISSUED: September, 2006
Supersedes: April, 2006
Doc.# 84018000, ECN# 060870, Rev. 5
assembly lightly lubricate valve O-ring with teflon based grease.
e. Reinsert valve assembly and bottom spring. Align bottom plug so that
tabs match body slots and arrow points in the direction of air flow.
f. Before returning to service, insure that all seals have been reinstalled
or replaced.
g. Insert flat head screwdriver into bottom plug slot, lightly press downward
and slowly rotate clockwise to securely lock bottom plug in place.
3.TO REPLACE OR SERVICE DIAPHRAGM ASSEMBLY:
a. Depressurize unit.
b. Turn adjusting knob counterclockwise to relieve compression on spring.
c. Remove bonnet from body by turning counterclockwise.
d. Remove main spring.
e. Remove diaphragm assembly to clean or replace.
f. Reinstall diaphragm assembly with spring rest in the up position.
g. Place main spring on spring rest.
h. Align bonnet assembly into body. Turn bonnet clockwise and tighten to
5 lb/ft (6-8 N-m).
i. Slowly pressurize unit to assume proper seating of all components.
4.IF UNIT WILL NOT REGULATE TO DESIRED PRESSURE OR IF
DOWNSTREAM PRESSURE BECOMES EXCESSIVE, disassemble, clean
and check valve O-ring, valve stem and valve seat for wear or damage.
Replace worn or damaged parts with original manufacturer's service parts.
ACCESSORIES
T-Type Bracket ...................................................................... GPA-96-737
C-Type Bracket ..................................................................... GPA-97-010
L-Type Bracket ...................................................................... GRP-96-739
Joiner Set ............................................................................. GPA-96-738
Piping Adapter Set, 1/8" NPT .............................................. GPA-97-018
Piping Adapter Set, 1/4" NPT .............................................. GPA-97-019
Piping Adapter Set, 3/8" NPT .............................................. GPA-97-020
Piping Adapter Set, G 1/8 .................................................... GPA-97-066
Piping Adapter Set, G 1/4 .................................................... GPA-97-067
Piping Adapter Set, G 3/8 .................................................... GPA-97-065
Piping Adapter Set w/T-Bracket, 1/8" NPT .......................... GPA-97-025
Piping Adapter Set w/T-Bracket, 1/4" NPT .......................... GPA-97-026
Piping Adapter Set w/T-Bracket, 3/8" NPT .......................... GPA-97-027
Piping Adapter Set w/T-Bracket, G 1/8 ................................ GPA-97-068
Piping Adapter Set w/T-Bracket, G 1/4 ................................ GPA-97-069
Piping Adapter Set w/T-Bracket, G 3/8 ................................ GPA-97-070
Panel Mount Nut (Aluminum) ............................................... RPA-96-733
Panel Mount Nut (Plastic) .................................................... RPA-96-734
Tamper Resistant Kit ............................................................ RPA-96-735
Safety Lockout Valve, 1/8" NPT .......................................... V08-01-0000
Safety Lockout Valve, 1/4" NPT .......................................... V08-02-0000
Safety Lockout Valve, G 1/8 ............................................... V08-C1-0000
Safety Lockout Valve, G 1/4 ............................................... V08-C2-0000
Diverter Block, 1/8" NPT ..................................................... N08-01-0000
Diverter Block, 1/4" NPT ..................................................... N08-02-0000
Diverter Block, G 1/8 .......................................................... N08-C1-0000
Diverter Block, G 1/4 .......................................................... N08-C2-0000
Diverter Block (w/check) 1/8" NPT .................................... N08-01-C000
Diverter Block (w/check) 1/4" NPT .................................... N08-02-C000
Diverter Block (w/check) G 1/8 .......................................... N08-C1-C000
Diverter Block (w/check) G 1/4 .......................................... N08-C2-C000
WARNING
!
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS
AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE
DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries and
authorized distributors provide product and/or system options for further investigation
by users having technical expertise. It is important that you analyze all aspects of
your application, including consequences of any failure and review the information
concerning the product or systems in the current product catalog. Due to the
variety of operating conditions and applications for these products or systems, the
user, through its own analysis and testing, is solely responsible for making the
final selection of the products and systems and assuring that all performance,
safety and warning requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by The
Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN
EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.
CONTACT YOUR LOCAL REPRESENTATIVE.

Publicidad

loading

Resumen de contenidos para Wilkerson R08

  • Página 1 Installation & Service Instructions 84-018-000 Regulator Model R08 Richland, MI 49083 Tel: (269) 629-5000 With Variations and Accessories ISSUED: September, 2006 Supersedes: April, 2006 WARNING Doc.# 84018000, ECN# 060870, Rev. 5 To avoid unpredictable system behavior that can cause personal injury and assembly lightly lubricate valve O-ring with teflon based grease.
  • Página 2 Instructions d'installation et Service 84-018-000 (French) Régulateur modèle R08 avec Richland, MI 49083 Tel: (269) 629-5000 Variations et Accessoires DISTRIBUE: Septembre, 2006 Supplantent: Avril, 2006 AVERTISSEMENT Doc.# 84018000, ECN# 060870, Rev. 5 Afin d’éviter un fonctionnement imprévu du système pouvant occasionner e.
  • Página 3: Instalacion

    Las Instrucciones de la instalación y el Servicio 84-018-000 (Spanish) Regulador Modelo R08 Richland, MI 49083 Tel: (269) 629-5000 con Variaciones y Accesorios PUBLICADO: Septiembre, 2006 ADVERTENCIA Desbancan: Abril, 2006 Doc.# 84018000, ECN# 060870, Rev. 5 Para evitar un comportamiento impredecible del sistema que pueda ocasionar lesiones personales y daños a la propiedad:...
  • Página 4 (31.7 mm) (31.7 mm) REGULATOR MODEL R08 WITH FLUSH MOUNT GAUGE REGULATOR MODEL R08 WITHOUT GAUGE RÉGULATEUR MODÈLE R08 AVEC MANOMÈTRE À MONTAGE ENCASTRÉ RÉGULATEUR MODÈLE R08 SANS MANOMÈTRE REGULADOR MODELO R08 CON MANOMETRO EMBUTIDO REGULADOR MODELO R08 SIN MANOMETRO...
  • Página 5 84-018-000 REPAIR KITS AND REPLACEMENT PARTS TROUSSES DE RÉPARATION ET PIÈCES DE RECHANGE JUEGOS DE REPARACION Y REPUESTOS Main spring Main spring Main spring Diaphragm Diaphragm Bottom Plug 0-125 psig 0-60 psig 0-30 psig Assembly Assembly Valve Bottom Valve O-Ring (0-9 bar) range (0-4 bar) range (0-2 bar) range...
  • Página 6 84-018-000 • Regulator Model R08 with Variations and Accessories • Régulateur modèle R08 avec variations et accessoires • Regulador Modelo R08 con Variaciones y Accesorios BOTTOM PLUG BOUCHON INFÉRIEUR TAPON INFERIOR O-RING JOINT TORIQUE JUNTA TORICA VALVE SPRING RESSORT DE SOUPAPE...